Skip to content
Fencer Vulns
high 8.0

CVE-2025-20386 json

Incorrect permission assignment on Splunk Enterprise for Windows during new installation or upgrade

published 2025-12-03 11 mo ago modified 2026-06-17 4 mo ago also EUVD-2025-201003

cvss
8.0
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.5%
EPSS 0.5% chance of exploitation in 30 days, percentile 42%
public exploits
0
none known

Summary

In Splunk Enterprise for Windows versions below 10.0.2, 9.4.6, 9.3.8, and 9.2.10, a new installation of or an upgrade to an affected version can result in incorrect permissions assignment in the Splunk Enterprise for Windows Installation directory. This lets non-administrator users on the machine access the directory and all its contents.

Patch / fix

  • Splunk Splunk Enterprise 9.2.10, 9.3.8, 9.4.6, 10.0.2

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
total
Assessed
11 mo ago

Exploit prediction

0.50% chance of exploitation in the next 30 days, higher than 42% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 3.1 8.0 CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
NVD 3.1 6.5 CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N

Affected products

  • Splunk Splunk Enterprise

Classification

Weakness
  • CWE-732 Incorrect Permission Assignment for Critical Resource

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.