CVE-2025-20060 json
Dario Health USB-C Blood Glucose Monitoring System Starter Kit Android Application Exposure of Private Personal Information to an Unauthorized Actor
published 2025-02-28 20 mo ago modified 2026-06-17 4 mo ago also EUVD-2025-5947
- cvss
- 7.5
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.4%
- EPSS 0.4% chance of exploitation in 30 days, percentile 34%
- public exploits
- 0
- none known
Summary
An attacker could expose cross-user personal identifiable information (PII) and personal health information transmitted to the Android device via the Dario Health application database.
Patch / fix
- Dario Health USB-C Blood Glucose Monitoring System Starter Kit Android Applications 5.8.7.0.36
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSMA-25-058-01 updated cvss 7.5
Dario Health USB-C Blood Glucose Monitoring System Starter Kit Android Application
-
Dario Health Dario Application Database and Internet-based Server Infrastructure Dario Health USB-C Blood Glucose Monitoring System Starter Kit Android Applications <=5.8.7.0.36affected: mitigation “Dario Health recommends users update their Dario Health Android mobile application to the latest version. No other actions are required by users.” dariohealth.com
From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf
CISA SSVC
- Exploitation
- none
- Automatable
- yes
- Technical impact
- partial
- Assessed
- 20 mo ago
Exploit prediction
0.40% chance of exploitation in the next 30 days, higher than 34% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 7.5 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N |
| CNA | 4.0 | 8.7 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N |
| CNA | 4.0 | 8.7 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
Affected products
- Dario Health USB-C Blood Glucose Monitoring System Starter Kit Android Applications
- Dario Health Dario Application Database and Internet-based Server Infrastructure
Classification
- Weakness
-
- CWE-359 Exposure of Private Personal Information to an Unauthorized Actor