CVE-2025-15574 json
Insecure Credential Generation for Solax Power Pocket WiFi models MQTT Cloud Connection
published 2026-02-12 8 mo ago modified 2026-06-17 4 mo ago also EUVD-2025-207388
- cvss
- 6.5
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.2%
- EPSS 0.2% chance of exploitation in 30 days, percentile 11%
- public exploits
- 0
- none known
Summary
When connecting to the Solax Cloud MQTT server the username is the "registration number", which is the 10 character string printed on the SolaX Power Pocket device / the QR code on the device. The password is derived from the "registration number" using a proprietary XOR/transposition algorithm. Attackers with the knowledge of the registration numbers can connect to the MQTT server and impersonate the dongle / inverters.
CISA SSVC
- Exploitation
- none
- Automatable
- yes
- Technical impact
- partial
- Assessed
- 8 mo ago
Exploit prediction
0.21% chance of exploitation in the next 30 days, higher than 11% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CISA ADP | 3.1 | 6.5 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N |
| CNA | 3.1 | 6.5 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N |
Affected products
- SolaX Power Pocket WiFi 3.0
- SolaX Power Pocket WiFi+LAN
- SolaX Power Pocket WiFi+4GM
- SolaX Power Pocket WiFi+LAN 2.0
- SolaX Power Pocket WiFi 4.0
Classification
- Weakness
-
- CWE-330 Use of Insufficiently Random Values
References
Sources
- CVE List CVE-2025-15574
- NVD CVE-2025-15574
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.