Skip to content
Fencer Vulns
high 7.3

CVE-2025-15502 json

Sangfor Operation and Maintenance Management System session SessionController os command injection

published 2026-01-10 9 mo ago modified 2026-06-17 4 mo ago also EUVD-2026-1855

cvss
7.3
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
6.1%
EPSS 6.1% chance of exploitation in 30 days, percentile 93%
public exploits
0
none known

Summary

A vulnerability was identified in Sangfor Operation and Maintenance Management System up to 3.0.8. The affected element is the function SessionController of the file /isomp-protocol/protocol/session. Such manipulation of the argument Hostname leads to os command injection. The attack can be executed remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.

CISA SSVC

Exploitation
Proof of concept is public
Automatable
yes
Technical impact
partial
Assessed
9 mo ago

Exploit prediction

6.05% chance of exploitation in the next 30 days, higher than 93% of all scored CVEs (FIRST EPSS, 2026-11-08).

Exploits and checks

  • github.com https://github.com/master-abc/cve/issues/14#issue-3770634476 referenced PoC, tagged "exploit" by a source, unverified
  • github.com https://github.com/master-abc/cve/issues/14 referenced PoC, tagged "exploit" by a source, unverified

CVSS scores

assigned by version score vector
CNA 4.0 6.9 CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P
CNA 3.1 7.3 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R
CNA 3.0 7.3 CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R
CNA 2.0 7.5 AV:N/AC:L/Au:N/C:P/I:P/A:P/E:POC/RL:ND/RC:UR
CNA 4.0 5.5 CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CNA 3.1 7.3 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L
NVD 3.1 9.8 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CNA 2.0 7.5 AV:N/AC:L/Au:N/C:P/I:P/A:P

Affected products

  • Sangfor Operation and Maintenance Management System

Classification

Weakness
  • CWE-78 Improper Neutralization of Special Elements used in an OS Command
  • CWE-77 Improper Neutralization of Special Elements used in a Command

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.