Skip to content
Fencer Vulns
low 3.5

CVE-2025-15258 json

Edimax BR-6208AC Web-based Configuration formALGSetup redirect

published 2025-12-30 10 mo ago modified 2026-06-17 4 mo ago also EUVD-2025-205831

cvss
3.5
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.3%
EPSS 0.3% chance of exploitation in 30 days, percentile 18%
public exploits
0
none known

Summary

A weakness has been identified in Edimax BR-6208AC 1.02/1.03. Affected by this issue is the function formALGSetup of the file /goform/formALGSetup of the component Web-based Configuration Interface. This manipulation of the argument wlan-url causes open redirect. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be used for attacks. Edimax confirms this issue: "The product mentioned, EDIMAX BR-6208AC V2, has reached its End of Life (EOL) status. It is no longer supported or maintained by Edimax, and it is no longer available for purchase in the market. Consequently, there will be no further firmware updates or patches for this device. We recommend users upgrade to newer models for better security." This vulnerability only affects products that are no longer supported by the maintainer.

CISA SSVC

Exploitation
Proof of concept is public
Automatable
no
Technical impact
partial
Assessed
10 mo ago

Exploit prediction

0.26% chance of exploitation in the next 30 days, higher than 18% of all scored CVEs (FIRST EPSS, 2026-11-08).

Exploits and checks

  • tzh00203.notion.site https://tzh00203.notion.site/EDIMAX-BR-6208AC-V2_1-02-Open-Redirect-Vulnerability-in-Web-formALGSetup-handler-2d3b5c52018a80188e9ae30d3cc8c3d1?source=copy_link referenced PoC, tagged "exploit" by a source, unverified

CVSS scores

assigned by version score vector
CNA 4.0 5.1 CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P
CNA 3.1 3.5 CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:C
CNA 3.0 3.5 CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:C
CNA 2.0 4.0 AV:N/AC:L/Au:S/C:N/I:P/A:N/E:POC/RL:ND/RC:C
CNA 4.0 2.0 CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CNA 3.1 3.5 CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:N
NVD 3.1 6.1 CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
CNA 2.0 4.0 AV:N/AC:L/Au:S/C:N/I:P/A:N

Affected products

  • Edimax BR-6208AC

Classification

Weakness
  • CWE-601 URL Redirection to Untrusted Site

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.