CVE-2025-14136 json
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 mod_form.so stack-based overflow
published 2025-12-06 11 mo ago modified 2026-09-25 44 d ago also EUVD-2025-201548
- cvss
- 8.8
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 1.2%
- EPSS 1.2% chance of exploitation in 30 days, percentile 68%
- public exploits
- 0
- none known
Summary
A security flaw has been discovered in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function RE2000v2Repeater_get_wired_clientlist_setClientsName of the file mod_form.so. The manipulation of the argument clientsname_0 results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way.
CISA SSVC
- Exploitation
- Proof of concept is public
- Automatable
- no
- Technical impact
- total
- Assessed
- 11 mo ago
Exploit prediction
1.22% chance of exploitation in the next 30 days, higher than 68% of all scored CVEs (FIRST EPSS, 2026-11-08).
Exploits and checks
- github.com https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_65/65.md#poc referenced PoC, tagged "exploit" by a source, unverified
- github.com https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_65/65.md referenced PoC, tagged "exploit" by a source, unverified
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 4.0 | 8.7 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P |
| CNA | 3.1 | 8.8 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R |
| CNA | 3.0 | 8.8 | CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R |
| CNA | 2.0 | 9.0 | AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR |
| CNA | 4.0 | 7.4 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
| CNA | 3.1 | 8.8 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
| CNA | 2.0 | 9.0 | AV:N/AC:L/Au:S/C:C/I:C/A:C |
Affected products
- Linksys RE6500
- Linksys RE6250
- Linksys RE6300
- Linksys RE6350
- Linksys RE7000
- Linksys RE9000
Classification
References
-
github.com
/wudipjq/my_vuln/blob/main/Linksys2/vuln_65/65.md#poc
exploit, third-party-advisory
-
github.com
/wudipjq/my_vuln/blob/main/Linksys2/vuln_65/65.md
related, exploit
-
vuldb.com
/?id.334525
vdb-entry, technical-description, third-party-advisory
-
vuldb.com
/?ctiid.334525
signature, permissions-required, vdb-entry
-
vuldb.com
/?submit.697983
third-party-advisory, vdb-entry
-
linksys.com
/
product
Sources
- CVE List CVE-2025-14136
- NVD CVE-2025-14136
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.