CVE-2025-14135 json
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 mod_form.so AP_get_wired_clientlist_setClientsName stack-based overflow
published 2025-12-06 11 mo ago modified 2026-09-25 44 d ago also EUVD-2025-201547
- cvss
- 8.8
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.9%
- EPSS 0.9% chance of exploitation in 30 days, percentile 61%
- public exploits
- 0
- none known
Summary
A vulnerability was identified in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This affects the function AP_get_wired_clientlist_setClientsName of the file mod_form.so. The manipulation of the argument clientsname_0 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.
CISA SSVC
- Exploitation
- Proof of concept is public
- Automatable
- no
- Technical impact
- total
- Assessed
- 11 mo ago
Exploit prediction
0.94% chance of exploitation in the next 30 days, higher than 61% of all scored CVEs (FIRST EPSS, 2026-11-08).
Exploits and checks
- github.com https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_64/64.md referenced PoC, tagged "exploit" by a source, unverified
- github.com https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_64/64.md#poc referenced PoC, tagged "exploit" by a source, unverified
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 4.0 | 8.7 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P |
| CNA | 3.1 | 8.8 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R |
| CNA | 3.0 | 8.8 | CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R |
| CNA | 2.0 | 9.0 | AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR |
| CNA | 4.0 | 7.4 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
| CNA | 3.1 | 8.8 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
| CNA | 2.0 | 9.0 | AV:N/AC:L/Au:S/C:C/I:C/A:C |
Affected products
- Linksys RE6500
- Linksys RE6250
- Linksys RE6300
- Linksys RE6350
- Linksys RE7000
- Linksys RE9000
Classification
References
-
github.com
/wudipjq/my_vuln/blob/main/Linksys2/vuln_64/64.md
related, exploit, third-party-advisory
-
github.com
/wudipjq/my_vuln/blob/main/Linksys2/vuln_64/64.md#poc
exploit, third-party-advisory
-
vuldb.com
/?id.334524
vdb-entry, technical-description, third-party-advisory
-
vuldb.com
/?ctiid.334524
signature, permissions-required, vdb-entry
-
vuldb.com
/?submit.697982
third-party-advisory, vdb-entry
-
linksys.com
/
product
Sources
- CVE List CVE-2025-14135
- NVD CVE-2025-14135