Skip to content
Fencer Vulns
medium 6.3

CVE-2025-12916 json

Sangfor Operation and Maintenance Security Management System Frontend portal_login command injection

published 2025-11-08 12 mo ago modified 2026-10-18 21 d ago also EUVD-2025-38438

cvss
6.3
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
5.1%
EPSS 5.1% chance of exploitation in 30 days, percentile 92%
public exploits
0
none known

Summary

A vulnerability was determined in Sangfor Operation and Maintenance Security Management System 3.0. Impacted is an unknown function of the file /fort/portal_login of the component Frontend. This manipulation of the argument loginUrl causes command injection. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized. Upgrading to version 3.0.11 and 3.0.12 is recommended to address this issue. It is advisable to upgrade the affected component.

Patch / fix

  • Sangfor Operation and Maintenance Security Management System 3.0.11, 3.0.12

CISA SSVC

Exploitation
Proof of concept is public
Automatable
no
Technical impact
partial
Assessed
11 mo ago

Exploit prediction

5.06% chance of exploitation in the next 30 days, higher than 92% of all scored CVEs (FIRST EPSS, 2026-11-08).

Exploits and checks

  • h4cker.zip https://h4cker.zip/post/fe0ada/ referenced PoC, tagged "exploit" by a source, unverified

CVSS scores

assigned by version score vector
CNA 4.0 5.3 CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P
CNA 3.1 6.3 CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:C
CNA 3.0 6.3 CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:C
CNA 2.0 6.5 AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:OF/RC:C
CNA 4.0 2.1 CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CNA 3.1 6.3 CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
NVD 3.1 9.8 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CNA 2.0 6.5 AV:N/AC:L/Au:S/C:P/I:P/A:P

Affected products

  • Sangfor Operation and Maintenance Security Management System

Classification

Weakness
  • CWE-77 Improper Neutralization of Special Elements used in a Command
  • CWE-74 Improper Neutralization of Special Elements in Output Used by a Downstream Component

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.