CVE-2025-12776 json
Stored Cross-Site Scripting
published 2026-01-07 10 mo ago modified 2026-06-17 4 mo ago also EUVD-2025-206259
- cvss
- 5.4
- version 3.1, NVD
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.2%
- EPSS 0.2% chance of exploitation in 30 days, percentile 7%
- public exploits
- 0
- none known
Summary
The Report Builder component of the application stores user input directly in a web page and displays it to other users, which raised concerns about a possible Cross-Site Scripting (XSS) attack. Proper management of this functionality helps ensure a secure and seamless user experience. Although the user input is not validated in the report creation, these scripts are not executed when the report is run by end users. The script is executed when the report is modified through the report builder by a user with edit permissions.
The Report Builder is part of the WebConsole. The WebConsole package is currently end of life, and is no longer maintained. We strongly recommend against installing or using it in any production environment. However, if you choose to install it, for example, to access functionality like the Report Builder, it must be deployed within a fully isolated network that has no access to sensitive data or internet connectivity. This is a critical security precaution, as the retired package may contain unpatched vulnerabilities and is no longer supported with updates or fixes.
Patch / fix
- Commvault WebConsole 11.40.1, 11.42.1
CISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- partial
- Assessed
- 10 mo ago
Exploit prediction
0.18% chance of exploitation in the next 30 days, higher than 7% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 4.0 | 1.8 | CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:A/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N |
| CNA | 4.0 | 1.8 | CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:A/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
| NVD | 3.1 | 5.4 | CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N |
Affected products
- Commvault WebConsole
Classification
- Weakness
-
- CWE-79 Improper Neutralization of Input During Web Page Generation
References
Sources
- CVE List CVE-2025-12776
- NVD CVE-2025-12776
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.