CVE-2025-1038 json
The “Diagnostics Tools” page of the web-based configuration utility does not properly validate user-controlled input, allowing an authentic…
published 2025-10-28 12 mo ago modified 2026-10-08 32 d ago also EUVD-2025-36506
- cvss
- 7.5
- version 4.0, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.3%
- EPSS 0.3% chance of exploitation in 30 days, percentile 25%
- public exploits
- 0
- none known
Summary
The “Diagnostics Tools” page of the web-based configuration utility does not properly validate user-controlled input, allowing an authenticated user with high privileges to inject commands into the command shell of the TropOS 4th Gen device. The injected commands can be exploited to execute several set-uid (SUID) applications to ultimately gain root access to the TropOS device.
Patch / fix
- Hitachi Energy TropOS 4th Gen 8.9.6.0
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-25-303-02 updated cvss 7.2
Hitachi Energy TropOS
-
Hitachi Energy TropOS 4th Gen Firmware <8.9.6.0affected: mitigation “For more information, see the associated Hitachi Energy cybersecurity advisory 8DBD000214 Multiple Vulnerabilities in Hitachi Energy TropOS 4th Gen Products: PDF Version, CSAF Version.” publisher.hitachienergy.com
From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf
CISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- total
- Assessed
- 12 mo ago
Exploit prediction
0.32% chance of exploitation in the next 30 days, higher than 25% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 4.0 | 7.5 | CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N |
| CNA | 4.0 | 7.5 | CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
Affected products
- Hitachi Energy TropOS 4th Gen
Classification
- Weakness
-
- CWE-78 Improper Neutralization of Special Elements used in an OS Command
References
Sources
- CVE List CVE-2025-1038
- NVD CVE-2025-1038
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.