CVE-2024-7847 json
RSLogix™ 5 and RSLogix 500® Remote Code Execution Via VBA Embedded Script
published 2024-10-14 2 y ago modified 2026-06-17 4 mo ago also EUVD-2024-48698
- cvss
- 7.7
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.2%
- EPSS 0.2% chance of exploitation in 30 days, percentile 8%
- public exploits
- 0
- none known
Summary
VULNERABILITY DETAILS
Rockwell Automation used the latest versions of the CVSS scoring system to assess the following vulnerabilities. The following vulnerabilities were reported to us by Sharon Brizinov of Claroty Research - Team82.
A feature in the affected products enables users to prepare a project file with an embedded VBA script and can be configured to run once the project file has been opened without user intervention. This feature can be abused to trick a legitimate user into executing malicious code upon opening an infected RSP/RSS project file. If exploited, a threat actor may be able to perform a remote code execution. Connected devices may also be impacted by exploitation of this vulnerability.
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-24-263-01 updated cvss 7.7
Rockwell Automation RSLogix 5 and RSLogix 500
-
Rockwell Automation RSLogix 5 Rockwell Automation RSLogix 500 Rockwell Automation RSLogix Micro Developer and Starteraffected: mitigation “Rockwell Automation offers users the following solutions:” rockwellautomation.com
From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf
CISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- total
- Assessed
- 2 y ago
Exploit prediction
0.18% chance of exploitation in the next 30 days, higher than 8% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 4.0 | 8.8 | CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H |
| CNA | 3.1 | 7.7 | CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H |
| CNA | 4.0 | 8.8 | CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
| NVD | 3.1 | 7.8 | CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H |
Affected products
- Rockwell Automation RSLogix 500®
- Rockwell Automation RSLogix™ Micro Developer and Starter
- Rockwell Automation RSLogix™ 5
- rockwellautomation rslogix_500
- rockwellautomation rslogix_micro_developer
- rockwellautomation rslogix_micro_starter
- rockwellautomation rslogix_5
Classification
- Weakness
-
- CWE-345 Insufficient Verification of Data Authenticity
References
Sources
- CVE List CVE-2024-7847
- NVD CVE-2024-7847
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.