CVE-2024-7715 json
D-Link DNS-1550-04 photocenter_mgr.cgi sprintf command injection
published 2024-08-13 2 y ago modified 2026-06-17 4 mo ago also EUVD-2024-48595
- cvss
- 6.3
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 26.2%
- EPSS 26.2% chance of exploitation in 30 days, percentile 98%
- public exploits
- 0
- none known
Summary
** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in D-Link DNS-120, DNR-202L, DNS-315L, DNS-320, DNS-320L, DNS-320LW, DNS-321, DNR-322L, DNS-323, DNS-325, DNS-326, DNS-327L, DNR-326, DNS-340L, DNS-343, DNS-345, DNS-726-4, DNS-1100-4, DNS-1200-05 and DNS-1550-04 up to 20240812. It has been classified as critical. This affects the function sprintf of the file /cgi-bin/photocenter_mgr.cgi. The manipulation of the argument filter leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the product is end-of-life. It should be retired and replaced.
CISA SSVC
- Exploitation
- Proof of concept is public
- Automatable
- no
- Technical impact
- partial
- Assessed
- 2 y ago
Exploit prediction
26.16% chance of exploitation in the next 30 days, higher than 98% of all scored CVEs (FIRST EPSS, 2026-11-08).
Exploits and checks
- github.com https://github.com/BuaaIOTTeam/Iot_Dlink_NAS/blob/main/DNS_cgi_photo_search.md referenced PoC, tagged "exploit" by a source, unverified
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 4.0 | 5.3 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N |
| CNA | 3.1 | 6.3 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L |
| CNA | 3.0 | 6.3 | CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L |
| CNA | 2.0 | 6.5 | AV:N/AC:L/Au:S/C:P/I:P/A:P |
| CNA | 4.0 | 5.3 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
Affected products
- D-Link DNS-120
- D-Link DNR-202L
- D-Link DNS-315L
- D-Link DNS-320
- D-Link DNS-320L
- D-Link DNS-320LW
- D-Link DNS-321
- D-Link DNR-322L
- D-Link DNS-323
- D-Link DNS-325
- D-Link DNS-326
- D-Link DNS-327L
- D-Link DNR-326
- D-Link DNS-340L
- D-Link DNS-343
- D-Link DNS-345
- D-Link DNS-726-4
- D-Link DNS-1100-4
- D-Link DNS-1200-05
- D-Link DNS-1550-04
- dlink dns-120_firmware
Classification
- Weakness
-
- CWE-77 Improper Neutralization of Special Elements used in a Command
References
-
github.com
/BuaaIOTTeam/Iot_Dlink_NAS/blob/main/DNS_cgi_photo_search.md
exploit
-
vuldb.com
/?id.274281
vdb-entry, technical-description
-
vuldb.com
/?ctiid.274281
signature, permissions-required
-
vuldb.com
/?submit.389261
third-party-advisory
-
supportannouncement.us.dlink.com
/security/publication.aspx?name=SAP10383
related
Sources
- CVE List CVE-2024-7715
- NVD CVE-2024-7715
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.