CVE-2024-7214 json
TOTOLINK LR350 cstecgi.cgi setWanCfg command injection
published 2024-07-30 2 y ago modified 2026-06-17 4 mo ago also EUVD-2024-48181
- cvss
- 6.3
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 3.2%
- EPSS 3.2% chance of exploitation in 30 days, percentile 88%
- public exploits
- 0
- none known
Summary
A vulnerability has been found in TOTOLINK LR350 9.3.5u.6369_B20220309 and classified as critical. Affected by this vulnerability is the function setWanCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument hostName leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-272785 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CISA SSVC
- Exploitation
- Proof of concept is public
- Automatable
- no
- Technical impact
- total
- Assessed
- 2 y ago
Exploit prediction
3.15% chance of exploitation in the next 30 days, higher than 88% of all scored CVEs (FIRST EPSS, 2026-11-08).
Exploits and checks
- github.com https://github.com/abcdefg-png/IoT-vulnerable/blob/main/TOTOLINK/LR350/setWanCfg.md referenced PoC, tagged "exploit" by a source, unverified
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 4.0 | 5.3 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N |
| CNA | 3.1 | 6.3 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L |
| CNA | 3.0 | 6.3 | CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L |
| CNA | 2.0 | 6.5 | AV:N/AC:L/Au:S/C:P/I:P/A:P |
| CNA | 4.0 | 5.3 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
| NVD | 3.1 | 8.8 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
Affected products
- TOTOLINK LR350
Classification
- Weakness
-
- CWE-77 Improper Neutralization of Special Elements used in a Command
References
-
github.com
/abcdefg-png/IoT-vulnerable/blob/main/TOTOLINK/LR350/setWanCfg.md
exploit
-
vuldb.com
/?id.272785
vdb-entry, technical-description, third-party-advisory
-
vuldb.com
/?ctiid.272785
signature, permissions-required
-
vuldb.com
/?submit.378319
third-party-advisory
Sources
- CVE List CVE-2024-7214
- NVD CVE-2024-7214