CVE-2024-6528 json
CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause a vulner…
published 2024-07-11 2 y ago modified 2026-06-17 4 mo ago also EUVD-2024-47608
- cvss
- 5.4
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.3%
- EPSS 0.3% chance of exploitation in 30 days, percentile 17%
- public exploits
- 0
- none known
Summary
CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause a vulnerability leading to a cross-site scripting condition where attackers can have a victim’s browser run arbitrary JavaScript when they visit a page containing the injected payload.
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-24-354-07 updated cvss 5.4
Schneider Electric Modicon Controllers (Update A)
-
Schneider Electric Modicon Controllers M241 <5.2.11.24 Schneider Electric Modicon Controllers M251 <5.2.11.24affected: mitigation “Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk:” se.com
-
Schneider Electric Modicon Controllers M258 / LMC058 <5.0.4.19 Schneider Electric Modicon Controllers M262 <5.2.8.26affected: fixed in v2.2.2, mitigation “Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk:” se.com
From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf
CISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- partial
- Assessed
- 2 y ago
Exploit prediction
0.26% chance of exploitation in the next 30 days, higher than 17% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 5.4 | CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N |
| NVD | 3.1 | 6.1 | CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N |
Affected products
- Schneider Electric Modicon Controllers M241 / M251
- Schneider Electric Modicon Controllers M258 / LMC058
- Schneider Electric Modicon Controllers M262
Classification
- Weakness
-
- CWE-79 Improper Neutralization of Input During Web Page Generation
References
Sources
- CVE List CVE-2024-6528
- NVD CVE-2024-6528
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.