CVE-2024-6273 json
SourceCodester Clinic Queuing System patient_side.php save_patient cross site scripting
published 2024-06-23 2 y ago modified 2026-06-17 4 mo ago also EUVD-2024-47393
- cvss
- 4.3
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.6%
- EPSS 0.6% chance of exploitation in 30 days, percentile 49%
- public exploits
- 0
- none known
Summary
A vulnerability was found in SourceCodester Clinic Queuing System 1.0. It has been declared as problematic. Affected by this vulnerability is the function save_patient of the file patient_side.php. The manipulation of the argument Full Name/Contact/Address leads to cross site scripting. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-269485 was assigned to this vulnerability.
CISA SSVC
- Exploitation
- Proof of concept is public
- Automatable
- no
- Technical impact
- partial
- Assessed
- 2 y ago
Exploit prediction
0.60% chance of exploitation in the next 30 days, higher than 49% of all scored CVEs (FIRST EPSS, 2026-11-08).
Exploits and checks
- docs.google.com https://docs.google.com/document/d/14ExrgXqPQlgvjw2poqNzYzAOi-C5tda-XBJF513yzag/edit?usp=sharing referenced PoC, tagged "exploit" by a source, unverified
- github.com https://github.com/sgr-xd/CVEs/blob/main/CVE-2024-6273.md referenced PoC, tagged "exploit" by a source, unverified
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 4.0 | 6.9 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N |
| CNA | 3.1 | 4.3 | CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N |
| CNA | 3.0 | 4.3 | CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N |
| CNA | 2.0 | 5.0 | AV:N/AC:L/Au:N/C:N/I:P/A:N |
| CNA | 4.0 | 6.9 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
| NVD | 3.1 | 6.1 | CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N |
Affected products
- SourceCodester Clinic Queuing System
- sourcecodester clinic_queuing_system
Classification
- Weakness
-
- CWE-79 Improper Neutralization of Input During Web Page Generation
References
-
docs.google.com
/document/d/14ExrgXqPQlgvjw2poqNzYzAOi-C5tda-XBJF513yzag/edit?usp=sharing
exploit
-
github.com
/sgr-xd/CVEs/blob/main/CVE-2024-6273.md
related, exploit, third-party-advisory
-
vuldb.com
/?id.269485
vdb-entry, technical-description, third-party-advisory
-
vuldb.com
/?ctiid.269485
signature, permissions-required
-
vuldb.com
/?submit.362873
third-party-advisory, vdb-entry
Sources
- CVE List CVE-2024-6273
- NVD CVE-2024-6273
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.