CVE-2024-51446 json
A vulnerability has been identified in Polarion V2310 (All versions), Polarion V2404 (All versions < V2404.4).
published 2025-05-13 17 mo ago modified 2026-06-17 4 mo ago also EUVD-2024-54492
- cvss
- 6.5
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.3%
- EPSS 0.3% chance of exploitation in 30 days, percentile 27%
- public exploits
- 0
- none known
Summary
A vulnerability has been identified in Polarion V2310 (All versions), Polarion V2404 (All versions < V2404.4). The file upload feature of the affected application improperly sanitizes xml files. This could allow an authenticated remote attacker to conduct a stored cross-site scripting attack by uploading specially crafted xml files that are later downloaded and viewed by other users of the application.
Patch / fix
- Siemens Polarion V2404 V2404.4
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-25-135-11 updated cvss 6.5
Siemens Polarion
-
Siemens Polarion V2310affected: no fix planned
-
Siemens Polarion V2404 < V2404.4affected: fixed in V2404.4 support.sw.siemens.com
Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf
CISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- partial
- Assessed
- 17 mo ago
Exploit prediction
0.34% chance of exploitation in the next 30 days, higher than 27% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 6.5 | CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:L |
| CNA | 4.0 | 5.1 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:L/VA:N/SC:L/SI:L/SA:L |
| CNA | 4.0 | 5.1 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:L/VA:N/SC:L/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
| NVD | 3.1 | 5.4 | CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N |
Affected products
- Siemens Polarion V2310
- Siemens Polarion V2404
Classification
- Weakness
-
- CWE-79 Improper Neutralization of Input During Web Page Generation
References
-
cert-portal.siemens.com
/productcert/html/ssa-162255.html
vendor-advisory
Sources
- CVE List CVE-2024-51446
- NVD CVE-2024-51446
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.