Skip to content
Fencer Vulns
medium 6.5

CVE-2024-47505 json

Junos OS Evolved: Specific low privileged CLI commands and SNMP GET requests can trigger a resource leak #1

published 2024-10-11 2 y ago modified 2026-06-17 4 mo ago also EUVD-2024-42508

cvss
6.5
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.4%
EPSS 0.4% chance of exploitation in 30 days, percentile 33%
public exploits
0
none known

Summary

An Allocation of Resources Without Limits or Throttling vulnerability in the PFE management daemon (evo-pfemand) of Juniper Networks Junos OS Evolved allows an authenticated, network-based attacker to cause an FPC crash leading to a Denial of Service (DoS).When specific SNMP GET operations or specific low-priviledged CLI commands are executed, a GUID resource leak will occur, eventually leading to exhaustion and resulting in FPCs to hang. Affected FPCs need to be manually restarted to recover.

GUID exhaustion will trigger a syslog message like one of the following:

evo-pfemand[<pid>]: get_next_guid: Ran out of Guid Space ... evo-aftmand-zx[<pid>]: get_next_guid: Ran out of Guid Space ... The leak can be monitored by running the following command and taking note of the values in the rightmost column labeled Guids:

user@host> show platform application-info allocations app evo-pfemand/evo-pfemand

In case one or more of these values are constantly increasing the leak is happening.

This issue affects Junos OS Evolved:

* All versions before 21.4R3-S7-EVO, * 22.1 versions before 22.1R3-S6-EVO, * 22.2 versions before 22.2R3-EVO,

* 22.3 versions before 22.3R3-EVO, * 22.4 versions before 22.4R2-EVO.

Please note that this issue is similar to, but different from CVE-2024-47508 and CVE-2024-47509.

Patch / fix

  • Juniper Networks Junos OS Evolved 21.4R3-S7-EVO, 22.1R3-S6-EVO, 22.2R3-EVO, 22.3R3-EVO, 22.4R2-EVO

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
partial
Assessed
2 y ago

Exploit prediction

0.39% chance of exploitation in the next 30 days, higher than 33% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 3.1 6.5 CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
CNA 4.0 7.1 CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/AU:Y/RE:M
CNA 4.0 7.1 CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:X/V:X/RE:M/U:X

Affected products

  • Juniper Networks Junos OS Evolved

Classification

Weakness
  • CWE-770 Allocation of Resources Without Limits or Throttling

References

Sources