Skip to content
Fencer Vulns
high 7.8

CVE-2024-45472 json

A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All vers…

published 2024-10-08 2 y ago modified 2026-06-17 4 mo ago also EUVD-2024-41724

cvss
7.8
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.2%
EPSS 0.2% chance of exploitation in 30 days, percentile 14%
public exploits
0
none known

Summary

A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. An attacker could leverage this in conjunction with other vulnerabilities to execute code in the context of the current process.

Patch / fix

  • Siemens Teamcenter Visualization V14.2 V14.2.0.14
  • Siemens Teamcenter Visualization V14.3 V14.3.0.12
  • Siemens Teamcenter Visualization V2312 V2312.0008
  • Siemens Tecnomatix Plant Simulation V2302 V2302.0016
  • Siemens Tecnomatix Plant Simulation V2404 V2404.0005
  • siemens tecnomatix_plant_simulation 2302.0016, 2404.0005

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

cisa ICSA-24-284-13 updated cvss 7.8

Siemens Tecnomatix Plant Simulation

  • Siemens Tecnomatix Plant Simulation V2302 <V2302.0016
    affected: fixed in V2302.0016, mitigation
  • Siemens Tecnomatix Plant Simulation V2404 <V2404.0005
    affected: fixed in V2404.0005, mitigation

Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf

cisa ICSA-24-347-09 updated cvss 7.8

Siemens Teamcenter Visualization

  • Siemens Teamcenter Visualization V14.2 <V14.2.0.14
    affected: fixed in V14.2.0.14, mitigation
  • Siemens Teamcenter Visualization V14.3 <V14.3.0.12
    affected: fixed in V14.3.0.12, mitigation
  • Siemens Teamcenter Visualization V2312 <V2312.0008
    affected: fixed in V2312.0008, mitigation

Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
total
Assessed
2 y ago

Exploit prediction

0.24% chance of exploitation in the next 30 days, higher than 14% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 3.1 7.8 CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
CNA 4.0 7.3 CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
CNA 4.0 7.3 CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
NVD 3.1 7.8 CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Affected products

  • Siemens Teamcenter Visualization V14.2
  • Siemens Teamcenter Visualization V14.3
  • Siemens Teamcenter Visualization V2312
  • Siemens Tecnomatix Plant Simulation V2302
  • Siemens Tecnomatix Plant Simulation V2404
  • siemens tecnomatix_plant_simulation

Classification

Weakness
  • CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.