CVE-2024-43648 json
Authenticated command injection via <redacted>.exe <redacted> parameter
published 2025-01-09 21 mo ago modified 2026-06-17 4 mo ago also EUVD-2024-40392
- cvss
- 8.8
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 1.9%
- EPSS 1.9% chance of exploitation in 30 days, percentile 79%
- public exploits
- 0
- none known
Summary
Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user.
This issue affects Iocharger firmware for AC models before version 24120701.
Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H). A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y).
Patch / fix
- Iocharger Iocharger firmware for AC models 24120701
CISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- total
- Assessed
- 21 mo ago
Exploit prediction
1.87% chance of exploitation in the next 30 days, higher than 79% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 4.0 | 9.3 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/S:P/AU:Y |
| CISA ADP | 3.1 | 8.8 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
| CNA | 4.0 | 9.3 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:P/AU:Y/R:X/V:X/RE:X/U:X |
| CNA | 3.1 | 8.8 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
Affected products
- Iocharger Iocharger firmware for AC models