Skip to content
Fencer Vulns
medium 4.8

CVE-2024-41982 json

A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >…

published 2025-08-12 14 mo ago modified 2026-06-17 4 mo ago also EUVD-2024-54868

cvss
4.8
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.1%
EPSS 0.1% chance of exploitation in 30 days, percentile 0%
public exploits
0
none known

Summary

A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application does not have adequate encryption of sensitive information. This could allow an authenticated attacker to gain access of sensitive information.

Patch / fix

  • Siemens SmartClient modules Opcenter QL Home (SC) V2506
  • Siemens SOA Audit V2506
  • Siemens SOA Cockpit V2506

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

cisa ICSA-25-226-06 updated cvss 4.8

Siemens Opcenter Quality

  • Siemens SmartClient modules Opcenter QL Home (SC) >= 13.2, < 2506 Siemens SOA Audit >= 13.2, < 2506 Siemens SOA Cockpit >= 13.2, < 2506
    affected: fixed in V2506, mitigation support.sw.siemens.com

Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
partial
Assessed
14 mo ago

Exploit prediction

0.08% chance of exploitation in the next 30 days, higher than 0% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 3.1 4.8 CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C
CNA 4.0 5.9 CVSS:4.0/AV:A/AC:H/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N
CNA 4.0 5.9 CVSS:4.0/AV:A/AC:H/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CNA 3.1 4.8 CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N
NVD 3.1 5.7 CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N

Affected products

  • Siemens SmartClient modules Opcenter QL Home (SC)
  • Siemens SOA Audit
  • Siemens SOA Cockpit

Classification

Weakness
  • CWE-311 Missing Encryption of Sensitive Data

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.