An attacker with local access to machine where MicroSCADA X SYS600 is installed, could enable the session logging supporting the product an…
published 2024-08-27 2 y ago modified 2026-06-17 4 mo ago also EUVD-2024-32548
- cvss
- 8.2
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.2%
- EPSS 0.2% chance of exploitation in 30 days, percentile 12%
- public exploits
- 0
- none known
Summary
An attacker with local access to machine where MicroSCADA X SYS600 is installed, could enable the session logging supporting the product and try to exploit a session hijacking of an already established session. By default, the session logging level is not enabled and only users with administrator rights can enable it.
Patch / fix
- hitachienergy microscada_x_sys600 10.6
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-26-260-03 updated cvss 8.2
Hitachi Energy FACTS Control Platform (FCP)
-
Hitachi Energy FACTS Control Platform (FCP) 3.10.0, 3.12.0, 3.14.0, 3.15.0affected: mitigation
Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf
cisa ICSA-24-331-04 updated cvss 8.2
Hitachi Energy MicroSCADA Pro/X SYS600 (Update A)
-
Hitachi Energy MicroSCADA Pro/X SYS600 >=10.0, <10.2affected: fixed in 10.6
-
Hitachi Energy MicroSCADA Pro/X SYS600 10.6fixed
Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf
cisa ICSA-25-133-03 updated cvss 8.2
Hitachi Energy MACH GWS products
-
Hitachi Energy MACH GWS >=3.0.0.0, <=3.3.0.0affected: fixed in 3.4.0.0
-
Hitachi Energy MACH GWS 3.4.0.0fixed
Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf
CISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- total
- Assessed
- 2 y ago
Exploit prediction
0.22% chance of exploitation in the next 30 days, higher than 12% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 8.2 | CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H |
| NVD | 3.1 | 8.2 | CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H |
Affected products
- Hitachi Energy MicroSCADA SYS600
- hitachi microscada_x_sys600
Classification
- Weakness
-
- CWE-294 Authentication Bypass by Capture-replay
References