CVE-2024-39570 json
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 HF1).
published 2024-07-09 2 y ago modified 2026-06-17 4 mo ago also EUVD-2024-38094
- cvss
- 8.8
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 1.4%
- EPSS 1.4% chance of exploitation in 30 days, percentile 71%
- public exploits
- 0
- none known
Summary
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 HF1). Affected applications are vulnerable to command injection due to missing server side input sanitation when loading VxLAN configurations. This could allow an authenticated attacker to execute arbitrary code with root privileges.
Patch / fix
- Siemens SINEMA Remote Connect Server V3.2 HF1
- siemens sinema_remote_connect_server V3.2 HF1
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-24-193-09 updated cvss 8.8
Siemens SINEMA Remote Connect Server
-
Siemens SINEMA Remote Connect Server <V3.2_HF1affected: fixed in V3.2 support.industry.siemens.com
Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf
CISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- total
- Assessed
- 2 y ago
Exploit prediction
1.35% chance of exploitation in the next 30 days, higher than 71% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 8.8 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C |
| CNA | 4.0 | 8.7 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N |
| CNA | 4.0 | 8.7 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
| CNA | 3.1 | 8.8 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
| NVD | 3.1 | 8.8 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
Affected products
- Siemens SINEMA Remote Connect Server
- siemens sinema_remote_connect_server
Classification
- Weakness
-
- CWE-77 Improper Neutralization of Special Elements used in a Command
References
-
cert-portal.siemens.com
/productcert/html/ssa-928781.html
patch, vendor-advisory
Sources
- CVE List CVE-2024-39570
- NVD CVE-2024-39570