CVE-2024-33494 json

A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manag…

published 2024-05-14 2 y ago modified 2026-06-17 4 mo ago also EUVD-2024-31232

cvss
6.5
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.3%
EPSS 0.3% chance of exploitation in 30 days, percentile 20%
public exploits
0
none known

Summary

A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected components do not properly authenticate heartbeat messages. This could allow an unauthenticated remote attacker to affected the availability of secondary RTLS systems configured using a TeeRevProxy service and potentially cause loss of data generated during the time the attack is ongoing.

Patch / fix

  • Siemens SIMATIC RTLS Locating Manager V3.0.1.1
  • siemens simatic_rtls_locating_manager 3.0.1.1

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

cisa ICSA-24-137-07 updated cvss 6.5

Siemens SIMATIC RTLS Locating Manager

  • Siemens SIMATIC RTLS Locating Manager (6GT2780-0DA00) <V3.0.1.1 Siemens SIMATIC RTLS Locating Manager (6GT2780-0DA10) <V3.0.1.1 Siemens SIMATIC RTLS Locating Manager (6GT2780-0DA20) <V3.0.1.1 Siemens SIMATIC RTLS Locating Manager (6GT2780-0DA30) <V3.0.1.1 Siemens SIMATIC RTLS Locating Manager (6GT2780-1EA10) <V3.0.1.1 Siemens SIMATIC RTLS Locating Manager (6GT2780-1EA20) <V3.0.1.1
    +1 more products
    Siemens SIMATIC RTLS Locating Manager (6GT2780-1EA30) <V3.0.1.1
    affected: fixed in V3.0.1.1, mitigation

Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
partial
Assessed
2 y ago

Exploit prediction

0.28% chance of exploitation in the next 30 days, higher than 20% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 3.1 6.5 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L/E:P/RL:O/RC:C
CNA 4.0 6.9 CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:L/SC:N/SI:N/SA:N
CNA 4.0 6.9 CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CNA 3.1 6.5 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L

Affected products

  • Siemens SIMATIC RTLS Locating Manager
  • siemens simatic_rtls_locating_manager

Classification

Weakness
  • CWE-345 Insufficient Verification of Data Authenticity

References