CVE-2024-29175 json
Dell PowerProtect Data Domain, versions prior to 7.13.0.0, LTS 7.7.5.40, LTS 7.10.1.30 contain an weak cryptographic algorithm vulnerabilit…
published 2024-06-26 2 y ago modified 2026-06-17 4 mo ago also EUVD-2024-26208
- cvss
- 5.9
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.3%
- EPSS 0.3% chance of exploitation in 30 days, percentile 17%
- public exploits
- 0
- none known
Summary
Dell PowerProtect Data Domain, versions prior to 7.13.0.0, LTS 7.7.5.40, LTS 7.10.1.30 contain an weak cryptographic algorithm vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to man-in-the-middle attack that exposes sensitive session information.
Patch / fix
- Dell PowerProtect DD 2.7.7, 5.16.0.0
- dell powerprotect_dd 2.7.7, 5.16.0.0
CISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- total
- Assessed
- 2 y ago
Exploit prediction
0.26% chance of exploitation in the next 30 days, higher than 17% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 5.9 | CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N |
| NVD | 3.1 | 5.9 | CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N |
Affected products
- Dell PowerProtect DD
- dell powerprotect_dd
Classification
- Weakness
-
- CWE-327 Use of a Broken or Risky Cryptographic Algorithm
References
Sources
- CVE List CVE-2024-29175
- NVD CVE-2024-29175
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.