CVE-2024-29082 json
Vonets WiFi Bridges Improper Access Control
published 2024-08-08 2 y ago modified 2026-06-17 4 mo ago also EUVD-2024-34439
- cvss
- 8.6
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.8%
- EPSS 0.8% chance of exploitation in 30 days, percentile 56%
- public exploits
- 0
- none known
Summary
Improper access control vulnerability affecting Vonets
industrial wifi bridge relays and wifi bridge repeaters, software versions 3.3.23.6.9 and prior, enables an unauthenticated remote attacker to bypass authentication and factory reset the device via unprotected goform endpoints.
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-24-214-08 updated cvss 8.6
Vonets WiFi Bridges
-
Vonets VAP11AC <=3.3.23.6.9 Vonets VAP11G <=3.3.23.6.9 Vonets VAP11G-300 <=3.3.23.6.9 Vonets VAP11G-500 <=3.3.23.6.9 Vonets VAP11G-500S <=3.3.23.6.9 Vonets VAP11N-300 <=3.3.23.6.9affected: mitigation “Vonets has not responded to requests to work with CISA to mitigate these vulnerabilities. Users of the affected products are encouraged to contact Vonets support for additional information.”
+8 more productsfewer
Vonets VAP11S <=3.3.23.6.9 Vonets VAP11S-5G <=3.3.23.6.9 Vonets VAR11N-300 <=3.3.23.6.9 Vonets VAR600-H <=3.3.23.6.9 Vonets VAR1200-H <=3.3.23.6.9 Vonets VAR1200-L <=3.3.23.6.9 Vonets VBG1200 <=3.3.23.6.9 Vonets VGA-1000 <=3.3.23.6.9
From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf
CISA SSVC
- Exploitation
- none
- Automatable
- yes
- Technical impact
- partial
- Assessed
- 2 y ago
Exploit prediction
0.80% chance of exploitation in the next 30 days, higher than 56% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 8.6 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H |
| CNA | 4.0 | 8.8 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N |
| CNA | 4.0 | 8.8 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
| NVD | 3.1 | 8.6 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H |
Affected products
- Vonets VAR1200-H
- Vonets VAR1200-L
- Vonets VAR600-H
- Vonets VAP11AC
- Vonets VAP11G-500S
- Vonets VBG1200
- Vonets VAP11S-5G
- Vonets VAP11S
- Vonets VAR11N-300
- Vonets VAP11G-300
- Vonets VAP11N-300
- Vonets VAP11G
- Vonets VAP11G-500
- Vonets VGA-1000
- vonets var1200-h_firmware
- vonets var1200-l_firmware
- vonets var600-h_firmware
- vonets vap11ac_firmware
- vonets vap11g-500s_firmware
- vonets vbg1200_firmware
- vonets vap11s-5g_firmware
- vonets vap11s_firmware
- vonets var11n-300_firmware
- vonets vap11n-300_firmware
- vonets vap11g_firmware
- vonets vga-1000_firmware
- vonets vap11g-300_firmware
Classification
- Weakness
-
- CWE-284 Improper Access Control
References
-
cisa.gov
/news-events/ics-advisories/icsa-24-214-08
third-party-advisory, us-government-resource
Sources
- CVE List CVE-2024-29082