Skip to content
Fencer Vulns
high 8.8

CVE-2024-23968 json

ChargePoint Home Flex SrvrToSmSetAutoChnlListMsg Stack-based Buffer Overflow

published 2025-01-30 21 mo ago modified 2026-06-17 4 mo ago also EUVD-2024-21394

cvss
8.8
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.5%
EPSS 0.5% chance of exploitation in 30 days, percentile 41%
public exploits
0
none known

Summary

This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of ChargePoint Home Flex charging stations. Authentication is not required to exploit this vulnerability.

The specific flaw exists within the SrvrToSmSetAutoChnlListMsg function. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of root.

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
total
Assessed
21 mo ago

Exploit prediction

0.48% chance of exploitation in the next 30 days, higher than 41% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 3.1 8.8 CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Affected products

  • ChargePoint Home Flex

Classification

Weakness
  • CWE-120 Buffer Copy without Checking Size of Input

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.