CVE-2024-23968 json
ChargePoint Home Flex SrvrToSmSetAutoChnlListMsg Stack-based Buffer Overflow
published 2025-01-30 21 mo ago modified 2026-06-17 4 mo ago also EUVD-2024-21394
- cvss
- 8.8
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.5%
- EPSS 0.5% chance of exploitation in 30 days, percentile 41%
- public exploits
- 0
- none known
Summary
This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of ChargePoint Home Flex charging stations. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the SrvrToSmSetAutoChnlListMsg function. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of root.
CISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- total
- Assessed
- 21 mo ago
Exploit prediction
0.48% chance of exploitation in the next 30 days, higher than 41% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 8.8 | CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
Affected products
- ChargePoint Home Flex
Classification
- Weakness
-
- CWE-120 Buffer Copy without Checking Size of Input
References
-
zerodayinitiative.com
/advisories/ZDI-24-1050/
third-party-advisory
Sources
- CVE List CVE-2024-23968
- NVD CVE-2024-23968
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.