CVE-2024-10914 in the critical feed json
D-Link DNS-320/DNS-320LW/DNS-325/DNS-340L account_mgr.cgi cgi_user_add os command injection
published 2024-11-06 2 y ago modified 2026-11-04 5 d ago also EUVD-2024-33344
- cvss
- 8.1
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 97.5%
- EPSS 97.5% chance of exploitation in 30 days, percentile 99.9%
- public exploits
- 1
- Exploit-DB, plus a Nuclei check
Summary
A vulnerability was found in D-Link DNS-320, DNS-320LW, DNS-325 and DNS-340L up to 20241028. It has been declared as critical. Affected by this vulnerability is the function cgi_user_add of the file /cgi-bin/account_mgr.cgi?cmd=cgi_user_add. The manipulation of the argument name leads to os command injection. The attack can be launched remotely. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used.
Timeline
- Published
- First public exploit (EDB-52643)
CISA SSVC
- Exploitation
- Proof of concept is public
- Automatable
- yes
- Technical impact
- total
- Assessed
- 23 mo ago
Exploit prediction
97.54% chance of exploitation in the next 30 days, higher than 99.9% of all scored CVEs (FIRST EPSS, 2026-11-08).
Exploits and checks
- EDB-52643 D-Link DNS_340L - OS Command Injection remote, 2026-08-17
- Nuclei template D-Link NAS - Command Injection via Name Parameter nuclei detection template
- netsecfish.notion.site https://netsecfish.notion.site/Command-Injection-Vulnerability-in-name-parameter-for-D-Link-NAS-12d6b683e67c80c49ffcc9214c239a07?pvs=4 referenced PoC, tagged "exploit" by a source, unverified
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 4.0 | 9.2 | CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N |
| CNA | 3.1 | 8.1 | CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H |
| CNA | 3.0 | 8.1 | CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H |
| CNA | 2.0 | 7.6 | AV:N/AC:H/Au:N/C:C/I:C/A:C |
| CNA | 4.0 | 9.2 | CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
| NVD | 3.1 | 9.8 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
Affected products
- D-Link DNS-320
- D-Link DNS-320LW
- D-Link DNS-325
- D-Link DNS-340L
- dlink dns-320_firmware
- dlink dns-320lw_firmware
- dlink dns-325_firmware
- dlink dns-340l_firmware
Classification
References
-
netsecfish.notion.site
/Command-Injection-Vulnerability-in-name-parameter-for-D-Link-NAS-12d6b683e67c80c49ffcc9214c239a07?pvs=4
exploit, third-party-advisory
-
vuldb.com
/?id.283309
vdb-entry, technical-description, permissions-required, third-party-advisory
-
vuldb.com
/?ctiid.283309
signature, permissions-required
-
vuldb.com
/?submit.432847
third-party-advisory
-
dlink.com
/
product
- bleepingcomputer.com /news/security/d-link-wont-fix-critical-flaw-affecting-60-000-older-nas-devices/
Sources
- CVE List CVE-2024-10914
- NVD CVE-2024-10914
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.