CVE-2024-10772 json
SICK InspectorP61x and SICK InspectorP62x are vulnerable for firmware modification
published 2024-12-06 23 mo ago modified 2026-06-17 4 mo ago also EUVD-2024-33530
- cvss
- 8.8
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.3%
- EPSS 0.3% chance of exploitation in 30 days, percentile 28%
- public exploits
- 0
- none known
Summary
Since the firmware update is not validated, an attacker can install modified firmware on the device. This has a high impact on the availabilty, integrity and confidentiality up to the complete compromise of the device.
Patch / fix
- SICK AG SICK InspectorP61x <5.0.0
- SICK AG SICK InspectorP62x <5.0.0
- sick inspector61x_firmware 5.0.0
- sick inspector62x_firmware 5.0.0
CISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- total
- Assessed
- 22 mo ago
Exploit prediction
0.34% chance of exploitation in the next 30 days, higher than 28% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 8.8 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
Affected products
- SICK AG SICK InspectorP61x
- SICK AG SICK InspectorP62x
- sick inspector61x_firmware
- sick inspector62x_firmware
Classification
- Weakness
-
- CWE-649 Reliance on Obfuscation or Encryption of Security-Relevant Inputs without Integrity Checking
References
-
sick.com
/.well-known/csaf/white/2024/sca-2024-0006.pdf
vendor-advisory
-
sick.com
/.well-known/csaf/white/2024/sca-2024-0006.json
vendor-advisory
- sick.com /psirt
- cdn.sick.com /media/docs/1/11/411/Special_information_CYBERSECURITY_BY_SICK_en_IM0084411.PDF
- cisa.gov /resources-tools/resources/ics-recommended-practices
- first.org /cvss/calculator/3.1
Sources
- CVE List CVE-2024-10772
- NVD CVE-2024-10772
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.