CVE-2023-7009 json
CVE-2023-7009
published 2024-03-15 2 y ago modified 2026-06-17 4 mo ago also EUVD-2023-59201
- cvss
- 8.2
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.2%
- EPSS 0.2% chance of exploitation in 30 days, percentile 16%
- public exploits
- 0
- none known
Summary
Some Sciener-based locks support plaintext message processing over Bluetooth Low Energy, allowing unencrypted malicious commands to be passed to the lock. These malicious commands, less then 16 bytes in length, will be processed by the lock as if they were encrypted communications. This can be further exploited by an attacker to compromise the lock's integrity.
CISA SSVC
- Exploitation
- Proof of concept is public
- Automatable
- yes
- Technical impact
- partial
- Assessed
- 2 y ago
Exploit prediction
0.25% chance of exploitation in the next 30 days, higher than 16% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CISA ADP | 3.1 | 8.2 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:N |
| CNA | 3.1 | 8.2 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:N |
Affected products
- Sciener Kontrol Lux
- sciener kontrol_lux_firmware
References
Sources
- CVE List CVE-2023-7009
- NVD CVE-2023-7009