Skip to content
Fencer Vulns
high 7.8

CVE-2023-53123 json

PCI: s390: Fix use-after-free of PCI resources with per-function hotplug

published 2025-05-02 18 mo ago modified 2026-11-05 3 d ago also EUVD-2025-13151

cvss
7.8
version 3.1, NVD
cisa kev
Not listed
not in CISA's catalog
epss
0.2%
EPSS 0.2% chance of exploitation in 30 days, percentile 8%
public exploits
0
none known

Summary

In the Linux kernel, the following vulnerability has been resolved:

PCI: s390: Fix use-after-free of PCI resources with per-function hotplug

On s390 PCI functions may be hotplugged individually even when they belong to a multi-function device. In particular on an SR-IOV device VFs may be removed and later re-added.

In commit a50297cf8235 ("s390/pci: separate zbus creation from scanning") it was missed however that struct pci_bus and struct zpci_bus's resource list retained a reference to the PCI functions MMIO resources even though those resources are released and freed on hot-unplug. These stale resources may subsequently be claimed when the PCI function re-appears resulting in use-after-free.

One idea of fixing this use-after-free in s390 specific code that was investigated was to simply keep resources around from the moment a PCI function first appeared until the whole virtual PCI bus created for a multi-function device disappears. The problem with this however is that due to the requirement of artificial MMIO addreesses (address cookies) extra logic is then needed to keep the address cookies compatible on re-plug. At the same time the MMIO resources semantically belong to the PCI function so tying their lifecycle to the function seems more logical.

Instead a simpler approach is to remove the resources of an individually hot-unplugged PCI function from the PCI bus's resource list while keeping the resources of other PCI functions on the PCI bus untouched.

This is done by introducing pci_bus_remove_resource() to remove an individual resource. Similarly the resource also needs to be removed from the struct zpci_bus's resource list. It turns out however, that there is really no need to add the MMIO resources to the struct zpci_bus's resource list at all and instead we can simply use the zpci_bar_struct's resource pointer directly.

Patch / fix

  • Linux Linux 5.15.104, 6.1.21, 6.2.8, 6.3
  • linux Debian 14, Debian 13, Debian 12 6.1.25-1

debian advisories DEBIAN-CVE-2023-53123

  • linux Ubuntu 22.04 LTS 5.15.0-79.86
  • linux-aws Ubuntu 22.04 LTS 5.15.0-1042.47
  • linux-gcp Ubuntu 22.04 LTS 5.15.0-1039.47
  • linux-gke Ubuntu 22.04 LTS 5.15.0-1039.44
  • linux-ibm Ubuntu 22.04 LTS 5.15.0-1035.38
  • linux-kvm Ubuntu 22.04 LTS 5.15.0-1039.44
  • linux-azure Ubuntu 22.04 LTS 5.15.0-1045.52
  • linux-gkeop Ubuntu 22.04 LTS 5.15.0-1025.30

ubuntu advisories UBUNTU-CVE-2023-53123

Ubuntu security data © Canonical Ltd., from https://github.com/canonical/ubuntu-security-notices via OSV; changed: normalised to fixed package versions per release. CC BY-SA 4.0

  • kernel-64kb SLES 15 SP4-LTSS, SLE High Performance Computing 15 SP4-LTSS, SLE High Performance Computing 15 SP4-ESPOS 5.14.21-150400.24.167.1
  • kernel-syms SLES for SAP 15 SP4, SLES 15 SP4-LTSS, SLE High Performance Computing 15 SP4-LTSS +3 more 5.14.21-150400.24.167.1
  • kernel-source SLES for SAP 15 SP4, SLES 15 SP4-LTSS, SLE High Performance Computing 15 SP4-LTSS +3 more 5.14.21-150400.24.167.1
  • kernel-default SLES for SAP 15 SP4, SLES 15 SP4-LTSS, SLE Micro 5.4 +7 more 5.14.21-150400.24.167.1
  • kernel-zfcpdump SLES 15 SP4-LTSS, Manager Server 4.3 5.14.21-150400.24.167.1
  • kernel-obs-build SLES for SAP 15 SP4, SLES 15 SP4-LTSS, SLE High Performance Computing 15 SP4-LTSS +1 more 5.14.21-150400.24.167.1
  • kernel-default-base SLES for SAP 15 SP4, SLES 15 SP4-LTSS, SLE Micro 5.4 +5 more 5.14.21-150400.24.167.1.150400.24.84.1
  • kernel-64kb SLES 15 SP5-LTSS, SLE High Performance Computing 15 SP5-LTSS, SLE High Performance Computing 15 SP5-ESPOS 5.14.21-150500.55.110.1

suse advisories SUSE-SU-2025:02262-1SUSE-SU-2025:02173-1SUSE-SU-2025:01966-1SUSE-SU-2025:01918-1

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

red hat product security vex CVE-2023-53123 updated cvss 6.4

kernel: PCI: s390: Fix use-after-free of PCI resources with per-function hotplug

  • Red Hat Enterprise Linux 6 perf, kernel, python-perf, kernel-kdump, kernel-firmware, kernel-bootwrapper, +1 more Red Hat Enterprise Linux 7 perf, kernel, bpftool, kernel-rt, python-perf, kernel-kdump, +8 more Red Hat Enterprise Linux 8 perf, kernel, bpftool, kernel-rt, kernel-core, kernel-tools, +29 more
    affected: no fix planned “Out of support scope”
  • Red Hat Enterprise Linux 9 rv, perf, rtla, kernel, bpftool, libperf, +83 more
    affected: no fix available “Fix deferred”
  • Red Hat Enterprise Linux 10 kernel
    not affected: vulnerable code not present

Red Hat CSAF VEX © Red Hat, Inc., from https://security.access.redhat.com/data/csaf/v2/vex/; changed: reduced to product statuses and remediations. CC BY 4.0 · csaf

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
partial
Assessed
3 d ago

Exploit prediction

0.19% chance of exploitation in the next 30 days, higher than 8% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
NVD 3.1 7.8 CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Affected products

  • Linux Linux

Classification

Weakness
Technology feeds

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.