CVE-2023-51572 in the critical feed json
Voltronic Power ViewPower Pro getMacAddressByIp Command Injection Remote Code Execution Vulnerability
published 2024-04-01 2 y ago modified 2026-06-17 4 mo ago also EUVD-2023-56284
- cvss
- 9.8
- version 3.0, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 38.4%
- EPSS 38.4% chance of exploitation in 30 days, percentile 98%
- public exploits
- 0
- none known
Summary
Voltronic Power ViewPower Pro getMacAddressByIp Command Injection Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Voltronic Power ViewPower Pro. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the getMacAddressByIP function. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-21163.
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-24-023-03 updated cvss 9.8
Voltronic Power ViewPower Pro
-
Voltronic Power ViewPower Pro 2.0-22165affected: mitigation “Voltronic Power did not respond to CISA's attempts at coordination. Users of Voltronic Power products are encouraged to contact Voltronic Power and keep their systems up to date.”
From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf
CISA SSVC
- Exploitation
- none
- Automatable
- yes
- Technical impact
- total
- Assessed
- 2 y ago
Exploit prediction
38.42% chance of exploitation in the next 30 days, higher than 98% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.0 | 9.8 | CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
Affected products
- Voltronic Power ViewPower Pro
- voltronicpower viewpower_pro
Classification
- Weakness
-
- CWE-78 Improper Neutralization of Special Elements used in an OS Command
References
-