CVE-2023-46280 json
A vulnerability has been identified in Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions < V5.0 SP2),…
published 2024-05-14 2 y ago modified 2026-06-17 4 mo ago also EUVD-2023-50505
- cvss
- 6.5
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.3%
- EPSS 0.3% chance of exploitation in 30 days, percentile 17%
- public exploits
- 0
- none known
Summary
A vulnerability has been identified in Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions < V5.0 SP2), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 Upd5), SIMATIC NET PC Software V16 (All versions < V16 Update 8), SIMATIC NET PC Software V17 (All versions), SIMATIC NET PC Software V18 (All versions < V18 SP1), SIMATIC NET PC Software V19 (All versions < V19 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PDM V9.2 (All versions < V9.2 SP2 Upd3), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 Upd3), SIMATIC S7-PCT (All versions < V3.5 SP3 Update 6), SIMATIC STEP 7 V5 (All versions < V5.7 SP3), SIMATIC WinCC OA V3.17 (All versions), SIMATIC WinCC OA V3.18 (All versions < V3.18 P025), SIMATIC WinCC OA V3.19 (All versions < V3.19 P010), SIMATIC WinCC Runtime Advanced (All versions < V17 Update 8), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 6), SIMATIC WinCC Runtime Professional V17 (All versions < V17 Update 8), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5), SINAMICS Startdrive (All versions < V19 SP1), SINEC NMS (All versions < V3.0), SINUMERIK ONE virtual (All versions < V6.23), SINUMERIK PLC Programming Tool (All versions < V3.3.12), TIA Portal Cloud Connector (All versions < V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 4), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 2), SINEC NMS (All versions < V3.0 SP1). The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel.
Patch / fix
- Siemens SIMATIC Automation Tool V5.0 SP2
- Siemens SIMATIC BATCH V9.1 V9.1 SP2 Upd5
- Siemens SIMATIC NET PC Software V16 V16 Update 8
- Siemens SIMATIC NET PC Software V18 V18 SP1
- Siemens SIMATIC NET PC Software V19 V19 Update 2
- Siemens SIMATIC PCS 7 V9.1 V9.1 SP2 UC05
- Siemens SIMATIC PDM V9.2 V9.2 SP2 Upd3
- Siemens SIMATIC Route Control V9.1 V9.1 SP2 Upd3
- Siemens SIMATIC S7-PCT V3.5 SP3 Update 6
- Siemens SIMATIC STEP 7 V5 V5.7 SP3
- Siemens SIMATIC WinCC OA V3.18 V3.18 P025
- Siemens SIMATIC WinCC OA V3.19 V3.19 P010
- Siemens SIMATIC WinCC Runtime Advanced V17 Update 8
- Siemens SIMATIC WinCC Runtime Professional V16 V16 Update 6
- Siemens SIMATIC WinCC Runtime Professional V17 V17 Update 8
- Siemens SIMATIC WinCC Runtime Professional V18 V18 Update 4
- Siemens SIMATIC WinCC Runtime Professional V19 V19 Update 2
- Siemens SIMATIC WinCC V7.5 V7.5 SP2 Update 17
- Siemens SIMATIC WinCC V8.0 V8.0 Update 5
- Siemens SINAMICS Startdrive V19 SP1
- Siemens SINEC NMS V3.0, V3.0 SP1
- Siemens SINUMERIK ONE virtual V6.23
- Siemens SINUMERIK PLC Programming Tool V3.3.12
- Siemens TIA Portal Cloud Connector V2.0
- Siemens Totally Integrated Automation Portal (TIA Portal) V17 V17 Update 8
- Siemens Totally Integrated Automation Portal (TIA Portal) V18 V18 Update 4
- Siemens Totally Integrated Automation Portal (TIA Portal) V19 V19 Update 2
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-24-137-13 updated cvss 6.5
Siemens Industrial Products
-
Siemens Security Configuration Tool (SCT)affected: no fix planned
-
Siemens SIMATIC Automation Tool < 5.0.2affected: fixed in V5.0 support.industry.siemens.com
-
Siemens SIMATIC BATCH V9.1 < 9.1.2.5affected: fixed in V9.1 support.industry.siemens.com
-
Siemens SIMATIC NET PC Software V16 < 16.0.0.8affected: fixed in V16 support.industry.siemens.com
-
Siemens SIMATIC NET PC Software V17affected: no fix planned
-
Siemens SIMATIC NET PC Software V18 < 18.0.1affected: fixed in V18 support.industry.siemens.com
-
Siemens SIMATIC NET PC Software V19 < 19.0.0.2affected: fixed in V19 support.industry.siemens.com
-
Siemens SIMATIC PCS 7 V9.1 < 9.1.2.05affected: fixed in V9.1 support.industry.siemens.com
show 23 moreshow fewer
-
Siemens SIMATIC PDM V9.2 < 9.2.2.3affected: fixed in V9.2 support.industry.siemens.com
-
Siemens SIMATIC Route Control V9.1 < 9.1.2.3affected: fixed in V9.1 support.industry.siemens.com
-
Siemens SIMATIC S7-PCT < 3.5.3.6affected: fixed in V3.5 support.industry.siemens.com
-
Siemens SIMATIC STEP 7 V5 < 5.7.3affected: fixed in V5.7 support.industry.siemens.com
-
Siemens SIMATIC WinCC OA V3.17affected: no fix planned
-
Siemens SIMATIC WinCC OA V3.18 < 3.18.025affected: fixed in V3.18 winccoa.com
-
Siemens SIMATIC WinCC OA V3.19 < 3.19.010affected: fixed in V3.19 winccoa.com
-
Siemens SIMATIC WinCC Runtime Advanced < 17.0.8affected: fixed in V17 support.industry.siemens.com
-
Siemens SIMATIC WinCC Runtime Professional V16 < 16.0.0.6affected: fixed in V16 support.industry.siemens.com
-
Siemens SIMATIC WinCC Runtime Professional V17 < 17.0.0.8affected: fixed in V17 support.industry.siemens.com
-
Siemens SIMATIC WinCC Runtime Professional V18 < 18.0.0.4affected: fixed in V18 support.industry.siemens.com
-
Siemens SIMATIC WinCC Runtime Professional V19 < 19.0.0.2affected: fixed in V19 support.industry.siemens.com
-
Siemens SIMATIC WinCC V7.4affected: no fix planned
-
Siemens SIMATIC WinCC V7.5 < 7.5.2.17affected: fixed in V7.5 support.industry.siemens.com
-
Siemens SIMATIC WinCC V8.0 < 8.0.0.5affected: fixed in V8.0 support.industry.siemens.com
-
Siemens SINAMICS Startdrive < 19.1affected: fixed in V19 support.industry.siemens.com
-
Siemens SINUMERIK ONE virtual < 6.23affected: fixed in V6.23
-
Siemens SINUMERIK PLC Programming Tool < 3.3.12affected: fixed in V3.3.12
-
Siemens TIA Portal Cloud Connector < 2.0affected: fixed in V2.0 support.industry.siemens.com
-
Siemens Totally Integrated Automation Portal (TIA Portal) V15.1 Siemens Totally Integrated Automation Portal (TIA Portal) V16affected: no fix planned
-
Siemens Totally Integrated Automation Portal (TIA Portal) V17 < 17.0.8affected: fixed in V17 support.industry.siemens.com
-
Siemens Totally Integrated Automation Portal (TIA Portal) V18 < 18.0.4affected: fixed in V18 support.industry.siemens.com
-
Siemens Totally Integrated Automation Portal (TIA Portal) V19 < 19.0.2affected: fixed in V19 support.industry.siemens.com
Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf
cisa ICSA-24-319-04 updated cvss 6.5
Siemens SINEC NMS
-
Siemens SINEC NMS <V3.0_SP1affected: fixed in V3.0 support.industry.siemens.com
Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf
cisa ICSA-24-228-06 updated cvss 6.5
Siemens SINEC NMS
-
Siemens SINEC NMS <V3.0affected: fixed in V3.0 support.industry.siemens.com
Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf
CISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- partial
- Assessed
- 2 y ago
Exploit prediction
0.26% chance of exploitation in the next 30 days, higher than 17% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 6.5 | CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H/E:P/RL:O/RC:C |
| CNA | 4.0 | 8.2 | CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H |
| CNA | 4.0 | 8.2 | CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
| CNA | 3.1 | 6.5 | CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H |
Affected products
- Siemens Security Configuration Tool (SCT)
- Siemens SIMATIC Automation Tool
- Siemens SIMATIC BATCH V9.1
- Siemens SIMATIC NET PC Software V16
- Siemens SIMATIC NET PC Software V17
- Siemens SIMATIC NET PC Software V18
- Siemens SIMATIC NET PC Software V19
- Siemens SIMATIC PCS 7 V9.1
- Siemens SIMATIC PDM V9.2
- Siemens SIMATIC Route Control V9.1
- Siemens SIMATIC S7-PCT
- Siemens SIMATIC STEP 7 V5
- Siemens SIMATIC WinCC OA V3.17
- Siemens SIMATIC WinCC OA V3.18
- Siemens SIMATIC WinCC OA V3.19
- Siemens SIMATIC WinCC Runtime Advanced
- Siemens SIMATIC WinCC Runtime Professional V16
- Siemens SIMATIC WinCC Runtime Professional V17
- Siemens SIMATIC WinCC Runtime Professional V18
- Siemens SIMATIC WinCC Runtime Professional V19
- Siemens SIMATIC WinCC V7.4
- Siemens SIMATIC WinCC V7.5
- Siemens SIMATIC WinCC V8.0
- Siemens SINAMICS Startdrive
- Siemens SINEC NMS
- Siemens SINUMERIK ONE virtual
- Siemens SINUMERIK PLC Programming Tool
- Siemens TIA Portal Cloud Connector
- Siemens Totally Integrated Automation Portal (TIA Portal) V15.1
- Siemens Totally Integrated Automation Portal (TIA Portal) V16
- Siemens Totally Integrated Automation Portal (TIA Portal) V17
- Siemens Totally Integrated Automation Portal (TIA Portal) V18
- Siemens Totally Integrated Automation Portal (TIA Portal) V19
Classification
- Weakness
-
- CWE-125 Out-of-bounds Read
References
Sources
- CVE List CVE-2023-46280
- NVD CVE-2023-46280
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.