CVE-2023-45601 json
A vulnerability has been identified in Parasolid V35.0 (All versions < V35.0.262), Parasolid V35.1 (All versions < V35.1.250), Parasolid V3…
published 2023-10-10 3 y ago modified 2026-06-17 4 mo ago also EUVD-2023-49893
- cvss
- 7.8
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.2%
- EPSS 0.2% chance of exploitation in 30 days, percentile 16%
- public exploits
- 0
- none known
Summary
A vulnerability has been identified in Parasolid V35.0 (All versions < V35.0.262), Parasolid V35.1 (All versions < V35.1.250), Parasolid V36.0 (All versions < V36.0.169), Tecnomatix Plant Simulation V2201 (All versions < V2201.0009), Tecnomatix Plant Simulation V2302 (All versions < V2302.0003). The affected applications contain a stack overflow vulnerability while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21290)
Patch / fix
- siemens parasolid 35.0.262, 35.1.250, 36.0.169
- siemens tecnomatix 2201.0009, 2302.0003
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-23-285-10 updated cvss 7.8
Siemens Tecnomatix Plant Simulation
-
Siemens Parasolid V35.0 <V35.0.262affected: fixed in V35.0.262, mitigation support.sw.siemens.com
-
Siemens Parasolid V35.1 <V35.1.250affected: fixed in V35.1.250, mitigation support.sw.siemens.com
-
Siemens Parasolid V36.0 <V36.0.169affected: fixed in V36.0.169, mitigation support.sw.siemens.com
-
Siemens Tecnomatix Plant Simulation V2201 <V2201.0009affected: fixed in V2201.0009, mitigation support.sw.siemens.com
-
Siemens Tecnomatix Plant Simulation V2302 <V2302.0003affected: fixed in V2302.0003, mitigation support.sw.siemens.com
Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf
CISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- total
- Assessed
- 2 y ago
Exploit prediction
0.25% chance of exploitation in the next 30 days, higher than 16% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 7.8 | CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C |
| CNA | 3.1 | 7.8 | CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H |
| NVD | 3.1 | 7.8 | CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H |
Affected products
- Siemens Parasolid V35.0
- Siemens Parasolid V35.1
- Siemens Parasolid V36.0
- Siemens Tecnomatix Plant Simulation V2201
- Siemens Tecnomatix Plant Simulation V2302
Classification
References
-
cert-portal.siemens.com
/productcert/pdf/ssa-524778.pdf
patch, vendor-advisory
Sources
- CVE List CVE-2023-45601
- NVD CVE-2023-45601
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.