CVE-2023-4346 kev in the critical feed json

KNX devices that use KNX Connection Authorization and support Option 1 are, depending on the implementation, vulnerable to being locked and…

published 2023-08-29 3 y ago modified 2026-07-16 3 mo ago also EUVD-2023-54211

cvss
7.5
version 3.1, CNA
cisa kev
Exploited
added 2026-07-15
epss
1.4%
EPSS 1.4% chance of exploitation in 30 days, percentile 71%
public exploits
0
none known

Summary

KNX devices that use KNX Connection Authorization and support Option 1 are, depending on the implementation, vulnerable to being locked and users being unable to reset them to gain access to the device. The BCU key feature on the devices can be used to create a password for the device, but this password can often not be reset without entering the current password. If the device is configured to interface with a network, an attacker with access to that network could interface with the KNX installation, purge all devices without additional security options enabled, and set a BCU key, locking the device. Even if a device is not connected to a network, an attacker with physical access to the device could also exploit this vulnerability in the same way.

Patch / fix

cisa required action Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

cisa ICSA-23-236-01 updated cvss 7.5

KNX Protocol

  • KNX Association KNX devices using Connection Authorization Option 1 Style in which no BCU Key is currently set
    affected: mitigation knx.org

From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf

Timeline

  1. Published
  2. CISA SSVC: exploitation active
  3. Added to CISA KEV
  4. CISA patch deadline

Known exploited

Added
3 mo ago
Patch by
2026-07-29 (3 mo ago)
Ransomware
Not known
Required action
Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.
Vendor, product
KNX Association, KNX Protocol Connection Authorization Option 1
CISA name
KNX Association KNX Protocol Connection Authorization Option 1 Overly Restrictive Account Lockout Mechanism Vulnerability

CISA SSVC

Exploitation
Active, exploited in the wild
Automatable
yes
Technical impact
partial
Assessed
3 mo ago

Exploit prediction

1.36% chance of exploitation in the next 30 days, higher than 71% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 3.1 7.5 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
NVD 3.1 7.5 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Affected products

  • KNX Association KNX Protocol Connection Authorization Option 1

Classification

Weakness
  • CWE-645 Overly Restrictive Account Lockout Mechanism