Skip to content
Fencer Vulns
high 7.2

CVE-2023-39460 json

Triangle MicroWorks SCADA Data Gateway Event Log Directory Traversal Arbitrary File Creation Vulnerability

published 2024-05-03 2 y ago modified 2026-06-17 4 mo ago also EUVD-2023-43183

cvss
7.2
version 3.0, CNA
cisa kev
Not listed
not in CISA's catalog
epss
3.4%
EPSS 3.4% chance of exploitation in 30 days, percentile 89%
public exploits
0
none known

Summary

Triangle MicroWorks SCADA Data Gateway Event Log Directory Traversal Arbitrary File Creation Vulnerability. This vulnerability allows remote attackers to create arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.

The specific flaw exists within the creation of event logs. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root. Was ZDI-CAN-20534.

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
partial
Assessed
2 y ago

Exploit prediction

3.44% chance of exploitation in the next 30 days, higher than 89% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 3.0 7.2 CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Affected products

  • Triangle MicroWorks SCADA Data Gateway
  • trianglemicroworks scada_data_gateway

Classification

Weakness
  • CWE-22 Improper Limitation of a Pathname to a Restricted Directory

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.