Skip to content
Fencer Vulns
high 8.8

CVE-2023-38098 in the critical feed json

NETGEAR ProSAFE Network Management System UpLoadServlet Unrestricted File Upload Remote Code Execution Vulnerability

published 2024-05-03 2 y ago modified 2026-06-17 4 mo ago also EUVD-2023-41924

cvss
8.8
version 3.0, CNA
cisa kev
Not listed
not in CISA's catalog
epss
12.7%
EPSS 12.7% chance of exploitation in 30 days, percentile 96%
public exploits
1
Metasploit

Summary

NETGEAR ProSAFE Network Management System UpLoadServlet Unrestricted File Upload Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of NETGEAR ProSAFE Network Management System. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.

The specific flaw exists within the UpLoadServlet class. The issue results from the lack of proper validation of user-supplied data, which can allow the upload of arbitrary files. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-19720.

Patch / fix

  • netgear prosafe_network_management_system 1.7.0.20

Timeline

  1. First public exploit (Metasploit exploit/windows/http/netgear_nms_rce)
  2. Published

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
total
Assessed
2 y ago

Exploit prediction

12.66% chance of exploitation in the next 30 days, higher than 96% of all scored CVEs (FIRST EPSS, 2026-11-08).

Exploits and checks

CVSS scores

assigned by version score vector
CNA 3.0 8.8 CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
NVD 3.1 8.8 CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Affected products

  • NETGEAR ProSAFE Network Management System
  • netgear prosafe_network_management_system

Classification

Weakness
  • CWE-434 Unrestricted Upload of File with Dangerous Type

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.