Skip to content
Fencer Vulns
high 7.3

CVE-2023-32736 json

A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V1…

published 2024-11-12 23 mo ago modified 2026-06-17 4 mo ago also EUVD-2023-36961

cvss
7.3
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.2%
EPSS 0.2% chance of exploitation in 30 days, percentile 12%
public exploits
0
none known

Summary

A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 8), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 5), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 8), SIMATIC STEP 7 V18 (All versions < V18 Update 5), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 8), SIMATIC WinCC Unified V18 (All versions < V18 SP5), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 8), SIMATIC WinCC V18 (All versions < V18 SP5), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions < V17 Update 8), SIMOCODE ES V18 (All versions), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions < V17 Update 8), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions < V17 Update 8), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions < V4.6.0.1), TIA Portal Cloud V18 (All versions < V4.6.1.0). Affected products do not properly sanitize user-controllable input when parsing user settings. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.

Patch / fix

  • Siemens SIMATIC STEP 7 Safety V17 V17 Update 8
  • Siemens SIMATIC STEP 7 Safety V18 V18 Update 5
  • Siemens SIMATIC STEP 7 V17 V17 Update 8
  • Siemens SIMATIC STEP 7 V18 V18 Update 5
  • Siemens SIMATIC WinCC Unified V17 V17 Update 8
  • Siemens SIMATIC WinCC Unified V18 V18 SP5
  • Siemens SIMATIC WinCC V17 V17 Update 8
  • Siemens SIMATIC WinCC V18 V18 SP5
  • Siemens SIMOCODE ES V17 V17 Update 8
  • Siemens SIRIUS Safety ES V17 (TIA Portal) V17 Update 8
  • Siemens SIRIUS Soft Starter ES V17 (TIA Portal) V17 Update 8
  • Siemens TIA Portal Cloud V17 V4.6.0.1
  • Siemens TIA Portal Cloud V18 V4.6.1.0
  • siemens simatic_step_7 17, 17_update8, 18_update5
  • siemens simatic_s7-plcsim 17
  • siemens simatic_wincc 17, 17_update8, 18_update5
  • siemens simatic_wincc_unified 17, 17_update8, 18_update5
  • siemens simocode_es 17, 17_update8
  • siemens sinamics_startdrive 17, 18
  • siemens sirius_safety_es 17_update8

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

cisa ICSA-24-319-07 updated cvss 7.3

Siemens Engineering Platforms

  • Siemens SIMATIC S7-PLCSIM V16 Siemens SIMATIC S7-PLCSIM V17 Siemens SIMATIC STEP 7 Safety V16
    affected: mitigation, no fix planned
  • Siemens SIMATIC STEP 7 Safety V17 <V17_Update_8
    affected: fixed in V17, mitigation
  • Siemens SIMATIC STEP 7 Safety V18 <V18_Update_5
    affected: fixed in V18, mitigation
  • Siemens SIMATIC STEP 7 V16
    affected: mitigation, no fix planned
  • Siemens SIMATIC STEP 7 V17 <V17_Update_8
    affected: fixed in V17, mitigation
  • Siemens SIMATIC STEP 7 V18 <V18_Update_5
    affected: fixed in V18, mitigation
  • Siemens SIMATIC WinCC Unified V16
    affected: mitigation, no fix planned
  • Siemens SIMATIC WinCC Unified V17 <V17_Update_8
    affected: fixed in V17, mitigation
show 19 more
  • Siemens SIMATIC WinCC Unified V18 <V18_SP5
    affected: fixed in V18, mitigation
  • Siemens SIMATIC WinCC V16
    affected: mitigation, no fix planned
  • Siemens SIMATIC WinCC V17 <V17_Update_8
    affected: fixed in V17, mitigation
  • Siemens SIMATIC WinCC V18 <V18_SP5
    affected: fixed in V18, mitigation
  • Siemens SIMOCODE ES V16
    affected: mitigation, no fix planned
  • Siemens SIMOCODE ES V17 <V17_Update_8
    affected: fixed in V17, mitigation
  • Siemens SIMOCODE ES V18
    affected: fixed in V18, mitigation support.industry.siemens.com
  • Siemens SIMOTION SCOUT TIA V5.4 SP1
    affected: mitigation, no fix planned
  • Siemens SIMOTION SCOUT TIA V5.4 SP3
    affected: fixed in V17, mitigation support.industry.siemens.com
  • Siemens SIMOTION SCOUT TIA V5.5 SP1
    affected: fixed in V18, mitigation support.industry.siemens.com
  • Siemens SINAMICS Startdrive V16
    affected: mitigation, no fix planned
  • Siemens SINAMICS Startdrive V17
    affected: fixed in V17, mitigation support.industry.siemens.com
  • Siemens SINAMICS Startdrive V18
    affected: fixed in V18, mitigation support.industry.siemens.com
  • Siemens SIRIUS Safety ES V17 (TIA Portal) <V17_Update_8
    affected: fixed in V17, mitigation
  • Siemens SIRIUS Safety ES V18 (TIA Portal)
    affected: fixed in V18, mitigation support.industry.siemens.com
  • Siemens SIRIUS Soft Starter ES V17 (TIA Portal) <V17_Update_8
    affected: fixed in V17, mitigation
  • Siemens SIRIUS Soft Starter ES V18 (TIA Portal)
    affected: fixed in V18, mitigation support.industry.siemens.com
  • Siemens TIA Portal Cloud V16
    affected: mitigation, no fix planned
  • Siemens TIA Portal Cloud V17 <V4.6.0.1 Siemens TIA Portal Cloud V18 <V4.6.1.0
    affected: vendor fix, mitigation

Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
total
Assessed
23 mo ago

Exploit prediction

0.22% chance of exploitation in the next 30 days, higher than 12% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 3.1 7.3 CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C
CNA 4.0 7.0 CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
CNA 4.0 7.0 CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CNA 3.1 7.3 CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H

Affected products

  • Siemens SIMATIC S7-PLCSIM V16
  • Siemens SIMATIC S7-PLCSIM V17
  • Siemens SIMATIC STEP 7 Safety V16
  • Siemens SIMATIC STEP 7 Safety V17
  • Siemens SIMATIC STEP 7 Safety V18
  • Siemens SIMATIC STEP 7 V16
  • Siemens SIMATIC STEP 7 V17
  • Siemens SIMATIC STEP 7 V18
  • Siemens SIMATIC WinCC Unified V16
  • Siemens SIMATIC WinCC Unified V17
  • Siemens SIMATIC WinCC Unified V18
  • Siemens SIMATIC WinCC V16
  • Siemens SIMATIC WinCC V17
  • Siemens SIMATIC WinCC V18
  • Siemens SIMOCODE ES V16
  • Siemens SIMOCODE ES V17
  • Siemens SIMOCODE ES V18
  • Siemens SIMOTION SCOUT TIA V5.4 SP1
  • Siemens SIMOTION SCOUT TIA V5.4 SP3
  • Siemens SIMOTION SCOUT TIA V5.5 SP1
  • Siemens SINAMICS Startdrive V16
  • Siemens SINAMICS Startdrive V17
  • Siemens SINAMICS Startdrive V18
  • Siemens SIRIUS Safety ES V17 (TIA Portal)
  • Siemens SIRIUS Safety ES V18 (TIA Portal)
  • Siemens SIRIUS Soft Starter ES V17 (TIA Portal)
  • Siemens SIRIUS Soft Starter ES V18 (TIA Portal)
  • Siemens TIA Portal Cloud V16
  • Siemens TIA Portal Cloud V17
  • Siemens TIA Portal Cloud V18
  • siemens simatic_step_7
  • siemens simatic_s7-plcsim
  • siemens simatic_wincc
  • siemens simatic_wincc_unified
  • siemens simocode_es
  • siemens simotion_scout_tia
  • siemens sinamics_startdrive
  • siemens sirius_safety_es
  • siemens tia_portal_cloud

Classification

Weakness
  • CWE-502 Deserialization of Untrusted Data

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.