CVE-2023-31041 json
An issue was discovered in SysPasswordDxe in Insyde InsydeH2O with kernel 5.0 through 5.5.
published 2023-08-14 3 y ago modified 2026-06-17 4 mo ago also EUVD-2023-35378
- cvss
- 7.5
- version 3.1, NVD
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.4%
- EPSS 0.4% chance of exploitation in 30 days, percentile 30%
- public exploits
- 0
- none known
Summary
An issue was discovered in SysPasswordDxe in Insyde InsydeH2O with kernel 5.0 through 5.5. System password information could optionally be stored in cleartext, which might lead to possible information disclosure.
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-23-257-04 updated cvss 5.1
Siemens RUGGEDCOM APE1808 Products
-
Siemens RUGGEDCOM APE1808 ADM (6GK6015-0AL20-0GL0) <BIOS_V1.0.212N Siemens RUGGEDCOM APE1808 ADM CC (6GK6015-0AL20-0GL1) <BIOS_V1.0.212N Siemens RUGGEDCOM APE1808 CKP (6GK6015-0AL20-0GK0) <BIOS_V1.0.212N Siemens RUGGEDCOM APE1808 CKP CC (6GK6015-0AL20-0GK1) <BIOS_V1.0.212N Siemens RUGGEDCOM APE1808 CLOUDCONNECT (6GK6015-0AL20-0GM0) <BIOS_V1.0.212N Siemens RUGGEDCOM APE1808 CLOUDCONNECT CC (6GK6015-0AL20-0GM1) <BIOS_V1.0.212Naffected: fixed in V1.0.212N support.industry.siemens.com
+16 more productsfewer
Siemens RUGGEDCOM APE1808 ELAN (6GK6015-0AL20-0GP0) <BIOS_V1.0.212N Siemens RUGGEDCOM APE1808 ELAN CC (6GK6015-0AL20-0GP1) <BIOS_V1.0.212N Siemens RUGGEDCOM APE1808 SAM-L (6GK6015-0AL20-0GN0) <BIOS_V1.0.212N Siemens RUGGEDCOM APE1808 SAM-L CC (6GK6015-0AL20-0GN1) <BIOS_V1.0.212N Siemens RUGGEDCOM APE1808CLA-P (6GK6015-0AL20-1AA0) <BIOS_V1.0.212N Siemens RUGGEDCOM APE1808CLA-P CC (6GK6015-0AL20-1AA1) <BIOS_V1.0.212N Siemens RUGGEDCOM APE1808CLA-S1 (6GK6015-0AL20-1AB0) <BIOS_V1.0.212N Siemens RUGGEDCOM APE1808CLA-S1 CC (6GK6015-0AL20-1AB1) <BIOS_V1.0.212N Siemens RUGGEDCOM APE1808CLA-S3 (6GK6015-0AL20-1AD0) <BIOS_V1.0.212N Siemens RUGGEDCOM APE1808CLA-S3 CC (6GK6015-0AL20-1AD1) <BIOS_V1.0.212N Siemens RUGGEDCOM APE1808CLA-S5 (6GK6015-0AL20-1AF0) <BIOS_V1.0.212N Siemens RUGGEDCOM APE1808CLA-S5 CC (6GK6015-0AL20-1AF1) <BIOS_V1.0.212N Siemens RUGGEDCOM APE1808LNX (6GK6015-0AL20-0GH0) <BIOS_V1.0.212N Siemens RUGGEDCOM APE1808LNX CC (6GK6015-0AL20-0GH1) <BIOS_V1.0.212N Siemens RUGGEDCOM APE1808W10 (6GK6015-0AL20-0GJ0) <BIOS_V1.0.212N Siemens RUGGEDCOM APE1808W10 CC (6GK6015-0AL20-0GJ1) <BIOS_V1.0.212N
Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf
CISA SSVC
- Exploitation
- none
- Automatable
- yes
- Technical impact
- partial
- Assessed
- 2 y ago
Exploit prediction
0.36% chance of exploitation in the next 30 days, higher than 30% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| NVD | 3.1 | 7.5 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N |
Classification
- Weakness
-
- CWE-312 Cleartext Storage of Sensitive Information
References
-
insyde.com
/security-pledge/SA-2023047
vendor-advisory
Sources
- CVE List CVE-2023-31041
- NVD CVE-2023-31041