Skip to content
Fencer Vulns
critical 9.1

CVE-2023-0321 json

Disclosure of Sensitive Information on Campbell Scientific Products

published 2023-01-25 3 y ago modified 2026-06-17 4 mo ago also EUVD-2023-12384

cvss
9.1
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.9%
EPSS 0.9% chance of exploitation in 30 days, percentile 59%
public exploits
0
none known

Summary

Campbell Scientific dataloggers CR6, CR300, CR800, CR1000 and CR3000 may allow an attacker to download configuration files, which may contain sensitive information about the internal network. From factory defaults, the mentioned datalogges have HTTP and PakBus enabled. The devices, with the default configuration, allow this situation via the PakBus port. The exploitation of this vulnerability may allow an attacker to download, modify, and upload new configuration files.

CISA SSVC

Exploitation
Proof of concept is public
Automatable
yes
Technical impact
partial
Assessed
19 mo ago

Exploit prediction

0.89% chance of exploitation in the next 30 days, higher than 59% of all scored CVEs (FIRST EPSS, 2026-11-08).

Exploits and checks

  • hackplayers.com https://www.hackplayers.com/2023/01/cve-2023-0321-info-sensible-campbell.html referenced PoC, tagged "exploit" by a source, unverified

CVSS scores

assigned by version score vector
CNA 3.1 9.1 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
NVD 3.1 9.1 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N

Affected products

  • Campbell Scientific CR6
  • Campbell Scientific CR300
  • Campbell Scientific CR800
  • Campbell Scientific CR1000
  • Campbell Scientific CR3000

Classification

Weakness
  • CWE-200 Exposure of Sensitive Information to an Unauthorized Actor

References

Sources