CVE-2023-0011 json
Command Execution through Serial Interface of u-blox TOBY-L2
published 2023-12-20 2 y ago modified 2026-06-17 4 mo ago also EUVD-2023-12116
- cvss
- 7.6
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.5%
- EPSS 0.5% chance of exploitation in 30 days, percentile 41%
- public exploits
- 0
- none known
Summary
A flaw in the input validation in TOBY-L2 allows a user to execute arbitrary operating system commands using specifically crafted AT commands. This vulnerability requires physical access to the serial interface of the module or the ability to modify the system or software which uses its serial interface to send malicious AT commands.
Exploitation of the vulnerability gives full administrative (root) privileges to the attacker to execute any operating system command on TOBY-L2 which can lead to modification of the behavior of the module itself as well as the components connected with it (depending on its rights on other connected systems). It can further provide the ability to read system level files and hamper the availability of the module as well..
This issue affects TOBY-L2 series: TOBY-L200, TOBY-L201, TOBY-L210, TOBY-L220, TOBY-L280.
CISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- total
- Assessed
- 18 mo ago
Exploit prediction
0.48% chance of exploitation in the next 30 days, higher than 41% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 7.6 | CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H |
| NVD | 3.1 | 6.8 | CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
Affected products
- u-blox TOBY-L2
Classification
References
-
u-blox.com
/en/report-security-issues
vendor-advisory
Sources
- CVE List CVE-2023-0011
- NVD CVE-2023-0011
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.