CVE-2022-50975 json
Multiple Innomic VibroLine VLX and avibia AVLX allow unauthenticated access to device configuration
published 2026-02-02 9 mo ago modified 2026-06-17 4 mo ago also EUVD-2022-55952
- cvss
- 8.8
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.3%
- EPSS 0.3% chance of exploitation in 30 days, percentile 17%
- public exploits
- 0
- none known
Summary
An unauthenticated remote attacker is able to use an existing session id of a logged in user and gain full access to the device if configuration via ethernet is enabled.
Patch / fix
- Innomic VibroLine VLX1 HD 5.0 2.1.1866
- Innomic VibroLine VLX2 HD 5.0 2.1.1866
- Innomic VibroLine VLX4 HD 5.0 2.1.1866
- Innomic VibroLine VLX6 HD 5.0 2.1.1866
- Innomic VibroLine VLX8 HD 5.0 2.1.1866
- avibia AvibiaLine AVLX1 HD 5.0 2.1.1866
- avibia AvibiaLine AVLX2 HD 5.0 2.1.1866
- avibia AvibiaLine AVLX4 HD 5.0 2.1.1866
- avibia AvibiaLine AVLX6 HD 5.0 2.1.1866
- avibia AvibiaLine AVLX8 HD 5.0 2.1.1866
CISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- total
- Assessed
- 9 mo ago
Exploit prediction
0.26% chance of exploitation in the next 30 days, higher than 17% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 8.8 | CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H |
Affected products
- Innomic VibroLine VLX1 HD 5.0
- Innomic VibroLine VLX2 HD 5.0
- Innomic VibroLine VLX4 HD 5.0
- Innomic VibroLine VLX6 HD 5.0
- Innomic VibroLine VLX8 HD 5.0
- avibia AvibiaLine AVLX1 HD 5.0
- avibia AvibiaLine AVLX2 HD 5.0
- avibia AvibiaLine AVLX4 HD 5.0
- avibia AvibiaLine AVLX6 HD 5.0
- avibia AvibiaLine AVLX8 HD 5.0
- Innomic VibroLine VLE1 HD 5.0
- Innomic VibroLine VLE2 HD 5.0
- Innomic VibroLine VLE4 HD 5.0
- Innomic VibroLine VLE6 HD 5.0
- Innomic VibroLine VLE8 HD 5.0
- Innomic AvibiaLine AVLE1 HD 5.0
- Innomic AvibiaLine AVLE2 HD 5.0
- Innomic AvibiaLine AVLE4 HD 5.0
- Innomic AvibiaLine AVLE6 HD 5.0
- Innomic AvibiaLine AVLE8 HD 5.0
- Innomic VibroLine VLE1 HD 4.0
- Innomic VibroLine VLE2 HD 4.0
- Innomic VibroLine VLE4 HD 4.0
- Innomic VibroLine VLE6 HD 4.0
- Innomic VibroLine VLE8 HD 4.0
- Innomic VibroLine VLX1 HD 4.0
- Innomic VibroLine VLX2 HD 4.0
- Innomic VibroLine VLX4 HD 4.0
- Innomic VibroLine VLX6 HD 4.0
- Innomic VibroLine VLX8 HD 4.0
Classification
- Weakness
-
- CWE-346 Origin Validation Error