CVE-2022-47387 json
CODESYS: Multiple products prone to stack based out-of-bounds write
published 2023-05-15 3 y ago modified 2026-06-17 4 mo ago also EUVD-2022-50154
- cvss
- 8.8
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 1.3%
- EPSS 1.3% chance of exploitation in 30 days, percentile 71%
- public exploits
- 0
- none known
Summary
An authenticated remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution.
Patch / fix
- CODESYS CODESYS Control RTE (SL) V3.5.19.0
- CODESYS CODESYS Control RTE (for Beckhoff CX) SL V3.5.19.0
- CODESYS CODESYS Control Win (SL) V3.5.19.0
- CODESYS CODESYS Control Runtime System Toolkit V3.5.19.0
- CODESYS CODESYS Safety SIL2 Runtime Toolkit V3.5.19.0
- CODESYS CODESYS Safety SIL2 PSP V3.5.19.0
- CODESYS CODESYS HMI (SL) V3.5.19.0
- CODESYS CODESYS Development System V3 V3.5.19.0
- CODESYS CODESYS Control for BeagleBone SL V4.8.0.0
- CODESYS CODESYS Control for emPC-A/iMX6 SL V4.8.0.0
- CODESYS CODESYS Control for IOT2000 SL V4.8.0.0
- CODESYS CODESYS Control for Linux SL V4.8.0.0
- CODESYS CODESYS Control for PFC100 SL V4.8.0.0
- CODESYS CODESYS Control for PFC200 SL V4.8.0.0
- CODESYS CODESYS Control for PLCnext SL V4.8.0.0
- CODESYS CODESYS Control for Raspberry Pi SL V4.8.0.0
- CODESYS CODESYS Control for WAGO Touch Panels 600 SL V4.8.0.0
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-26-076-01 updated cvss 8.8
CODESYS in Festo Automation Suite
-
CODESYS Development System 3.0 Festo Automation Suite 2.8.0.137, Festo Automation Suite < 2.8.0.138 CODESYS Development System 3.5.16.10 Festo Automation Suite 2.8.0.137, Festo Automation Suite < 2.8.0.138affected: mitigation
-
Festo Automation Suite 2.8.0.138 CODESYS Development System 3.5.21.20fixed
Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf
cisa ICSA-26-020-02 updated cvss 8.8
Schneider Electric devices using CODESYS Runtime
-
Schneider Electric Easy Harmony HMIET6/HMIFT6 Magelis HMIGXU series <2.0_HF2affected: vendor fix se.com
-
Schneider Electric Easy Modicon M310 <3.1.5.82affected: vendor fix, mitigation se.com
-
Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series <6.3_HF3affected: fixed in v6.3
-
Schneider Electric Harmony iPC series Vijeo Designer runtime <6.3_SP2 Schneider Electric Harmony P6 series Vijeo Designer runtime <6.3_SP2affected: fixed in v6.3 se.com
-
Schneider Electric HMISCU Controller <6.3.1affected: fixed in v6.3.1, mitigation se.com
-
Schneider Electric Magelis XBT seriesaffected: no fix planned
-
Schneider Electric Modicon Controller LMC058affected: mitigation
-
Schneider Electric Modicon Controller M241 <5.2.11.18 Schneider Electric Modicon Controller M251 <5.2.11.18affected: fixed in v2.2, mitigation se.com
show 6 moreshow fewer
-
Schneider Electric Modicon Controller M258affected: mitigation
-
Schneider Electric Modicon Controller M262 <5.2.8.12affected: fixed in v2.2, mitigation se.com
-
Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 <1.76.14.1affected: fixed in V2.2, mitigation se.com
-
Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert <2.2affected: vendor fix, mitigation se.com
-
Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert <6.3.1affected: fixed in v6.3.1 se.com
-
Schneider Electric Easy Modicon M310 3.1.5.82 Schneider Electric Harmony (Formerly Magelis) HMIGK/HMIGTO/HMIGTU/HMIGTUX/HMISTU series iPC series with Vijeo Designer runtime 6.3_HF3 Schneider Electric Harmony iPC series Vijeo Designer runtime 6.3_SP2 Schneider Electric Harmony P6 series Vijeo Designer runtime 6.3_SP2 Schneider Electric HMISCU Controller 6.3.1 Schneider Electric Modicon Controller M241 5.2.11.18fixed
+6 more productsfewer
Schneider Electric Modicon Controller M251 5.2.11.18 Schneider Electric Modicon Controller M262 5.2.8.12 Schneider Electric PacDrive 3 Controllers: LMC Eco/Pro/Pro2 1.76.14.1 Schneider Electric SoftSPS embedded in EcoStruxure Machine Expert 2.2 Schneider Electric Vijeo Designer Basic 2.0_HotFix_2 Schneider Electric Vijeo Designer embedded in EcoStruxure Machine Expert 6.3.1
Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf
cisa ICSA-24-030-07 updated cvss 8.8
Rockwell Automation LP30/40/50 and BM40 Operator Interface
-
Rockwell Automation BM40 Operator Panel <V3.5.19.0 Rockwell Automation LP30 Operator Panel <V3.5.19.0 Rockwell Automation LP40 Operator Pane <V3.5.19.0 Rockwell Automation LP50 Operator Panel <V3.5.19.0affected: mitigation “Rockwell Automation recommends users with the affected software apply the following risk mitigations, if possible:” asem.it
From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf
CISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- total
- Assessed
- 20 mo ago
Exploit prediction
1.32% chance of exploitation in the next 30 days, higher than 71% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 8.8 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
Affected products
- CODESYS CODESYS Control RTE (SL)
- CODESYS CODESYS Control RTE (for Beckhoff CX) SL
- CODESYS CODESYS Control Win (SL)
- CODESYS CODESYS Control Runtime System Toolkit
- CODESYS CODESYS Safety SIL2 Runtime Toolkit
- CODESYS CODESYS Safety SIL2 PSP
- CODESYS CODESYS HMI (SL)
- CODESYS CODESYS Development System V3
- CODESYS CODESYS Control for BeagleBone SL
- CODESYS CODESYS Control for emPC-A/iMX6 SL
- CODESYS CODESYS Control for IOT2000 SL
- CODESYS CODESYS Control for Linux SL
- CODESYS CODESYS Control for PFC100 SL
- CODESYS CODESYS Control for PFC200 SL
- CODESYS CODESYS Control for PLCnext SL
- CODESYS CODESYS Control for Raspberry Pi SL
- CODESYS CODESYS Control for WAGO Touch Panels 600 SL
Classification
- Weakness
-
- CWE-787 Out-of-bounds Write
References
Sources
- CVE List CVE-2022-47387
- NVD CVE-2022-47387
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.