Skip to content
Fencer Vulns
high 7.8

CVE-2022-39136 json

A vulnerability has been identified in JT2Go (All versions < V14.1.0.4), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamce…

published 2022-11-08 4 y ago modified 2026-06-17 4 mo ago also EUVD-2022-41681

cvss
7.8
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.3%
EPSS 0.3% chance of exploitation in 30 days, percentile 26%
public exploits
0
none known

Summary

A vulnerability has been identified in JT2Go (All versions < V14.1.0.4), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamcenter Visualization V13.3 (All versions < V13.3.0.7), Teamcenter Visualization V13.3 (All versions >= V13.3.0.7 < V13.3.0.8), Teamcenter Visualization V14.0 (All versions < V14.0.0.3), Teamcenter Visualization V14.1 (All versions < V14.1.0.4). The affected application is vulnerable to fixed-length heap-based buffer while parsing specially crafted TIF files. An attacker could leverage this vulnerability to execute code in the context of the current process.

Patch / fix

  • siemens jt2go 14.1.0.4
  • siemens teamcenter_visualization 14.0.0.3, 14.1.0.4

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

cisa ICSA-22-314-09 updated cvss 7.8

Siemens Teamcenter Visualization and JT2Go

  • Siemens JT2Go <V14.1.0.4
    affected: fixed in V14.1.0.4, mitigation plm.automation.siemens.com
  • Siemens Teamcenter Visualization V13.2 <V13.2.0.12
    affected: fixed in V13.2.0.12, mitigation support.sw.siemens.com
  • Siemens Teamcenter Visualization V13.3 <V13.3.0.7, >=V13.3.0.7<V13.3.0.8
    affected: fixed in V13.3.0.7, mitigation support.sw.siemens.com
  • Siemens Teamcenter Visualization V14.0 <V14.0.0.3
    affected: fixed in V14.0.0.3, mitigation support.sw.siemens.com
  • Siemens Teamcenter Visualization V14.1 <V14.1.0.4
    affected: fixed in V14.1.0.4, mitigation support.sw.siemens.com

Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
total
Assessed
18 mo ago

Exploit prediction

0.33% chance of exploitation in the next 30 days, higher than 26% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 3.1 7.8 CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C
CNA 3.1 7.8 CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
NVD 3.1 7.8 CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Affected products

  • Siemens JT2Go
  • Siemens Teamcenter Visualization V13.2
  • Siemens Teamcenter Visualization V13.3
  • Siemens Teamcenter Visualization V14.0
  • Siemens Teamcenter Visualization V14.1

Classification

Weakness

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.