CVE-2022-36363 json

A vulnerability has been identified in LOGO!

published 2022-10-11 4 y ago modified 2026-06-17 4 mo ago also EUVD-2022-39078

cvss
5.3
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.5%
EPSS 0.5% chance of exploitation in 30 days, percentile 44%
public exploits
0
none known

Summary

A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). Affected devices do not properly validate an offset value which can be defined in TCP packets when calling a method. This could allow an attacker to retrieve parts of the content of the memory.

Patch / fix

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

cisa ICSA-22-286-13 updated cvss 5.3

Siemens LOGO! 8 BM Devices

  • Siemens LOGO! 12/24RCE (6ED1052-1MD08-0BA1) Siemens LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) Siemens LOGO! 24CE (6ED1052-1CC08-0BA1) Siemens LOGO! 24CEo (6ED1052-2CC08-0BA1) Siemens LOGO! 24RCE (6ED1052-1HB08-0BA1) Siemens LOGO! 24RCEo (6ED1052-2HB08-0BA1)
    +10 more products
    Siemens LOGO! 230RCE (6ED1052-1FB08-0BA1) Siemens LOGO! 230RCEo (6ED1052-2FB08-0BA1) Siemens SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) Siemens SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) Siemens SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) Siemens SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) Siemens SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) Siemens SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) Siemens SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) Siemens SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1)
    affected: workaround, mitigation, no fix planned

Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf

Exploit prediction

0.52% chance of exploitation in the next 30 days, higher than 44% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 3.1 5.3 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:T/RC:C
CNA 3.1 5.3 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N

Affected products

  • Siemens LOGO! 12/24RCE
  • Siemens LOGO! 12/24RCEo
  • Siemens LOGO! 230RCE
  • Siemens LOGO! 230RCEo
  • Siemens LOGO! 24CE
  • Siemens LOGO! 24CEo
  • Siemens LOGO! 24RCE
  • Siemens LOGO! 24RCEo
  • Siemens SIPLUS LOGO! 12/24RCE
  • Siemens SIPLUS LOGO! 12/24RCEo
  • Siemens SIPLUS LOGO! 230RCE
  • Siemens SIPLUS LOGO! 230RCEo
  • Siemens SIPLUS LOGO! 24CE
  • Siemens SIPLUS LOGO! 24CEo
  • Siemens SIPLUS LOGO! 24RCE
  • Siemens SIPLUS LOGO! 24RCEo

Classification

Weakness
  • CWE-1285 Improper Validation of Specified Index, Position, or Offset in Input
  • CWE-20 Improper Input Validation

References