CVE-2022-32513 json
A CWE-521: Weak Password Requirements vulnerability exists that could allow an attacker to gain control of the device when the attacker bru…
published 2023-01-30 3 y ago modified 2026-06-17 4 mo ago also EUVD-2022-35584
- cvss
- 9.8
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.7%
- EPSS 0.7% chance of exploitation in 30 days, percentile 53%
- public exploits
- 0
- none known
Summary
A CWE-521: Weak Password Requirements vulnerability exists that could allow an attacker to gain control of the device when the attacker brute forces the password. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)
Patch / fix
- Schneider Electric C-Bus Network Automation Controller, LSS5500NAC V1.10.0
- Schneider Electric Wiser for C-Bus Automation Controller, LSS5500SHAC V1.10.0
- Schneider Electric Clipsal C-Bus Network Automation Controller, 5500NAC V1.10.0
- Schneider Electric Clipsal Wiser for C-Bus Automation Controller, 5500SHAC V1.10.0
- Schneider Electric SpaceLogic C-Bus Network Automation Controller, 5500NAC2 V1.10.0
- Schneider Electric SpaceLogic C-Bus Application Controller, 5500AC2 V1.10.0
CISA SSVC
- Exploitation
- none
- Automatable
- yes
- Technical impact
- total
- Assessed
- 21 mo ago
Exploit prediction
0.69% chance of exploitation in the next 30 days, higher than 53% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 9.8 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
| NVD | 3.1 | 9.8 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
Affected products
- Schneider Electric C-Bus Network Automation Controller, LSS5500NAC
- Schneider Electric Wiser for C-Bus Automation Controller, LSS5500SHAC
- Schneider Electric Clipsal C-Bus Network Automation Controller, 5500NAC
- Schneider Electric Clipsal Wiser for C-Bus Automation Controller, 5500SHAC
- Schneider Electric SpaceLogic C-Bus Network Automation Controller, 5500NAC2
- Schneider Electric SpaceLogic C-Bus Application Controller, 5500AC2
Classification
- Weakness
-
- CWE-521 Weak Password Requirements
References
Sources
- CVE List CVE-2022-32513
- NVD CVE-2022-32513
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.