CVE-2022-31807 json

A vulnerability has been identified in Building X - Security Manager Edge Controller (ACC-AP) (All versions).

published 2025-05-23 17 mo ago modified 2026-06-17 4 mo ago also EUVD-2022-54259

cvss
6.2
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.2%
EPSS 0.2% chance of exploitation in 30 days, percentile 5%
public exploits
0
none known

Summary

A vulnerability has been identified in Building X - Security Manager Edge Controller (ACC-AP) (All versions). Affected devices do not properly check the integrity of firmware updates. This could allow a local attacker to upload a maliciously modified firmware onto the device. In a second scenario, a remote attacker who is able to intercept the transfer of a valid firmware from the server to the device could modify the firmware "on the fly".

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

cisa ICSA-25-345-07 updated cvss 6.2

Siemens Building X - Security Manager Edge Controller

  • Siemens Building X - Security Manager Edge Controller (ACC-AP)
    affected: mitigation, no fix planned

Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf

cisa ICSA-25-148-01 updated cvss 6.2

Siemens SiPass

  • Siemens SiPass integrated AC5102 (ACC-G2) Siemens SiPass integrated ACC-AP
    affected: mitigation, no fix planned

Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
partial
Assessed
17 mo ago

Exploit prediction

0.16% chance of exploitation in the next 30 days, higher than 5% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 3.1 6.2 CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
CNA 4.0 5.9 CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N
CNA 4.0 5.9 CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
NVD 3.1 5.5 CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N

Affected products

  • Siemens Building X - Security Manager Edge Controller (ACC-AP)

Classification

Weakness
  • CWE-347 Improper Verification of Cryptographic Signature