CVE-2022-31807 json
A vulnerability has been identified in Building X - Security Manager Edge Controller (ACC-AP) (All versions).
published 2025-05-23 17 mo ago modified 2026-06-17 4 mo ago also EUVD-2022-54259
- cvss
- 6.2
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.2%
- EPSS 0.2% chance of exploitation in 30 days, percentile 5%
- public exploits
- 0
- none known
Summary
A vulnerability has been identified in Building X - Security Manager Edge Controller (ACC-AP) (All versions). Affected devices do not properly check the integrity of firmware updates. This could allow a local attacker to upload a maliciously modified firmware onto the device. In a second scenario, a remote attacker who is able to intercept the transfer of a valid firmware from the server to the device could modify the firmware "on the fly".
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-25-345-07 updated cvss 6.2
Siemens Building X - Security Manager Edge Controller
-
Siemens Building X - Security Manager Edge Controller (ACC-AP)affected: mitigation, no fix planned
Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf
cisa ICSA-25-148-01 updated cvss 6.2
Siemens SiPass
-
Siemens SiPass integrated AC5102 (ACC-G2) Siemens SiPass integrated ACC-APaffected: mitigation, no fix planned
Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf
CISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- partial
- Assessed
- 17 mo ago
Exploit prediction
0.16% chance of exploitation in the next 30 days, higher than 5% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 6.2 | CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N |
| CNA | 4.0 | 5.9 | CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N |
| CNA | 4.0 | 5.9 | CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
| NVD | 3.1 | 5.5 | CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N |
Affected products
- Siemens Building X - Security Manager Edge Controller (ACC-AP)
Classification
- Weakness
-
- CWE-347 Improper Verification of Cryptographic Signature