CVE-2022-25922 json
ICSA-22-063-01 Missing Authentication for Critical Function in Trailer Power Line Communications (PLC) J2497
published 2022-03-07 4 y ago modified 2026-06-17 4 mo ago also EUVD-2022-30505
- cvss
- 6.1
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 1.2%
- EPSS 1.2% chance of exploitation in 30 days, percentile 68%
- public exploits
- 0
- none known
Summary
Power Line Communications PLC4TRUCKS J2497 trailer brake controllers implement diagnostic functions which can be invoked by replaying J2497 messages. There is no authentication or authorization for these functions.
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-22-063-01 updated cvss 6.1
Trailer Power Line Communications (PLC) J2497
-
n/a Power Line Communications (PLC) J2497affected: mitigation “Install a LAMP ON firewall for each ECU”
From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf
CISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- partial
- Assessed
- 18 mo ago
Exploit prediction
1.20% chance of exploitation in the next 30 days, higher than 68% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 6.1 | CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H |
| NVD | 3.1 | 9.1 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H |
| NVD | 2.0 | 6.4 | AV:N/AC:L/Au:N/C:N/I:P/A:P |
Affected products
- Power Line Communications PLC4TRUCKS
Classification
- Weakness
-
- CWE-306 Missing Authentication for Critical Functionality
References
-
cisa.gov
/uscert/ics/advisories/icsa-22-063-01
third-party-advisory, us-government-resource
Sources
- CVE List CVE-2022-25922
- NVD CVE-2022-25922
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.