CVE-2022-23450 in the critical feed json
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All version…
published 2022-04-12 4 y ago modified 2026-06-17 4 mo ago also EUVD-2022-28525
- cvss
- 9.8
- version 3.1, NVD
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 35.7%
- EPSS 35.7% chance of exploitation in 30 days, percentile 98%
- public exploits
- 0
- none known
Summary
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). The affected system allows remote users to send maliciously crafted objects. Due to insecure deserialization of user-supplied content by the affected software, an unauthenticated attacker could exploit this vulnerability by sending a maliciously crafted serialized object. This could allow the attacker to execute arbitrary code on the device with SYSTEM privileges.
Patch / fix
- siemens simatic_energy_manager_basic 7.3
- siemens simatic_energy_manager_pro 7.3
Vendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-22-104-11 updated cvss 10.0
Siemens SIMATIC Energy Manager
-
Siemens SIMATIC Energy Manager Basic <V7.3_Update_1 Siemens SIMATIC Energy Manager PRO <V7.3_Update_1affected: fixed in V7.3, mitigation support.industry.siemens.com
Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf
Exploit prediction
35.75% chance of exploitation in the next 30 days, higher than 98% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| NVD | 3.1 | 9.8 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
| NVD | 2.0 | 10.0 | AV:N/AC:L/Au:N/C:C/I:C/A:C |
Affected products
- Siemens SIMATIC Energy Manager Basic
- Siemens SIMATIC Energy Manager PRO
Classification
- Weakness
-
- CWE-502 Deserialization of Untrusted Data
References
-
cert-portal.siemens.com
/productcert/pdf/ssa-655554.pdf
mitigation, patch, vendor-advisory
Sources
- CVE List CVE-2022-23450
- NVD CVE-2022-23450
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.