Skip to content
Fencer Vulns
medium 5.7

CVE-2022-22558 json

Dell PowerEdge Server BIOS and Dell Precision Workstation 7910 and 7920 Rack BIOS contain an Improper SMM communication buffer verification…

published 2022-04-21 4 y ago modified 2026-06-17 4 mo ago also EUVD-2022-27704

cvss
5.7
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.2%
EPSS 0.2% chance of exploitation in 30 days, percentile 10%
public exploits
0
none known

Summary

Dell PowerEdge Server BIOS and Dell Precision Workstation 7910 and 7920 Rack BIOS contain an Improper SMM communication buffer verification vulnerability. A Local High Privileged attacker could potentially exploit this vulnerability leading to arbitrary writes or denial of service.

Patch / fix

  • Dell PowerEdge Platform BIOS update for PowerEdge 13G Intel 1S/2S and 14G AMD

Exploit prediction

0.21% chance of exploitation in the next 30 days, higher than 10% of all scored CVEs (FIRST EPSS, 2026-11-08).

CVSS scores

assigned by version score vector
CNA 3.1 5.7 CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:H/A:H
NVD 3.1 6.0 CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H
NVD 2.0 3.6 AV:L/AC:L/Au:N/C:N/I:P/A:P

Affected products

  • Dell PowerEdge Platform

Classification

Weakness
  • CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer

References

Sources

Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.