CVE-2022-22216 json
Junos OS: PTX Series and QFX10000 Series: 'Etherleak' memory disclosure in Ethernet padding data
published 2022-07-20 4 y ago modified 2026-06-17 4 mo ago also EUVD-2022-27363
- cvss
- 4.3
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.3%
- EPSS 0.3% chance of exploitation in 30 days, percentile 23%
- public exploits
- 0
- none known
Summary
An Exposure of Sensitive Information to an Unauthorized Actor vulnerability in the PFE of Juniper Networks Junos OS on PTX Series and QFX10k Series allows an adjacent unauthenticated attacker to gain access to sensitive information. PTX1000 and PTX10000 Series, and QFX10000 Series and PTX5000 Series devices sometimes do not reliably pad Ethernet packets, and thus some packets can contain fragments of system memory or data from previous packets. This issue is also known as 'Etherleak' and often detected as CVE-2003-0001. This issue affects: Juniper Networks Junos OS on PTX1000 and PTX10000 Series: All versions prior to 18.4R3-S11; 19.1 versions prior to 19.1R2-S3, 19.1R3-S7; 19.2 versions prior to 19.2R1-S8, 19.2R3-S4; 19.3 versions prior to 19.3R3-S4; 19.4 versions prior to 19.4R2-S5, 19.4R3-S6; 20.1 versions prior to 20.1R3-S2; 20.2 versions prior to 20.2R3-S3; 20.3 versions prior to 20.3R3-S2; 20.4 versions prior to 20.4R3-S4; 21.1 versions prior to 21.1R2-S1, 21.1R3; 21.2 versions prior to 21.2R1-S1, 21.2R2. Juniper Networks Junos OS on QFX10000 Series and PTX5000 Series: All versions prior to 18.3R3-S6; 18.4 versions prior to 18.4R2-S9, 18.4R3-S10; 19.1 versions prior to 19.1R2-S3, 19.1R3-S7; 19.2 versions prior to 19.2R1-S8, 19.2R3-S4; 19.3 versions prior to 19.3R3-S4; 19.4 versions prior to 19.4R2-S6, 19.4R3-S6; 20.1 versions prior to 20.1R3-S2; 20.2 versions prior to 20.2R3-S3; 20.3 versions prior to 20.3R3-S1; 20.4 versions prior to 20.4R3-S1; 21.1 versions prior to 21.1R2-S1, 21.1R3; 21.2 versions prior to 21.2R2.
Patch / fix
- Juniper Networks Junos OS 18.3R3-S6, 18.4R2-S9, 18.4R3-S10, 18.4R3-S11, 19.1R2-S3, 19.1R3-S7, 19.2R1-S8, 19.2R3-S4, 19.3R3-S4, 19.4R2-S5, 19.4R3-S6, 19.4R2-S6, 19.4R3-S6, 20.1R3-S2, 20.2R3-S3, 20.3R3-S1, 20.3R3-S2, 20.4R3-S1, 20.4R3-S4, 21.1R2-S1, 21.1R3, 21.2R1-S1, 21.2R2, 21.2R2
Exploit prediction
0.30% chance of exploitation in the next 30 days, higher than 23% of all scored CVEs (FIRST EPSS, 2026-11-08).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 4.3 | CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N |
| NVD | 3.1 | 4.3 | CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N |
Affected products
- Juniper Networks Junos OS
Classification
- Weakness
-
- CWE-200 Exposure of Sensitive Information to an Unauthorized Actor
References
-
kb.juniper.net
/JSA69720
vendor-advisory
Sources
- CVE List CVE-2022-22216
- NVD CVE-2022-22216
Fencer Vulns keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.